6th SENSE MODE
The sensor
in the indoor unit, which measures temperature and humidity in the room, keeps the room
temperature in the most comfortable level by controlling the temperature and the fan speed automatically.
Press the 6th SENSE button on the remote controller to enable it:
6th SENSE icon appears automatically on the remote control display, in cooling mode the air conditioner
will set the fan speed to auto, adjust the temperature and humidity automatically according to the
enviroment.
1. The unit will automatically sense the outdoor air tempearture every 3 hours and select the
operation mode for you, detail see below table.
Tod is= outdoor enviroment temeprature.
Note: Mode cannot be switched manually under 6th SENSE function.
2. In coolin
g mode, unit will automatically set a comfortable temperature and humidity for you,
you can adjust it base on your need, to adjust temperature by pressing the and button
on remote control. On the display , "0" to indicate the default, other number (-3, -2, -1, 0, 1, 2, 3)
corresponding to tempearture change as below:
3.
After setting
the desired temperature, there will be a new humidity setting display. You can
press the and to change the setting, the range is from -15% to 15% based on the
default setting.
Outdoor temp
erature range
Mode setting
25°C
Tod
COOLING
22°C
Tod < 2
5°C
FAN ONL
Y
22°C <
Tod
HEATING
Outdoor temp
erature range
Default mode Default setting Max Min
30°C
Tod
COOLING 22°C 25°C 19°C
25°C
Tod < 3
0°C
COOLING 21°C 24°C 18°C
22°C <
Tod
HEATING 22°C 25°C 19°C