Service Hatch and Air Supply
Example:
Bath laid on
supporting frame
Option A
Option B
A ventilation grid is
mandatory
Service hatch and air
supply
Position service hatches, at least
40 x 40 cm, near the motor and
blower depending on the model.
Position service hatches so that
parts such as blowers, pumps,
valves, connector boxes and
other connections are always
accessible and replaceable.
Removable side panels are
ideal (e.g. Mepa decorating
system). The air grid for the
blower air supply (150 cm
2
) can
be installed in this service hatch.
The service hatch can also be
located in a neighbouring room.
No liability will be accepted
for any costs arising from non-
observation of this information.
If the service hatch cannot be
installed in a neighbouring
room, it must be installed in the
bathroom. A splashproof grid
must also be installed here. We
recommend insulating the grid
against noise.
Alternative:
If there is not enough space for
a service hatch, we recommend
just „laying“ the bath on the
supporting frame so that the
complete bath can be removed
if necessary. In this case, it
must be possible to disconnect
the drain connection, electrical
connections and, if necessary,
the water supply via the
ventilation hatch.