Manual

Preparing the Laundry System for Exhausting Left or Right
1. Remove left or right side panel knockout by drilling four (4) holes at the drill locations
(dimples) shown and knock out plug. (Fig. 6) Use a file and remove the small burrs in the
hole created after the knockout is removed.
2.
Remove the two (2) 5/16-inch screws securing the exhaust pipe bracket to the laundry system.
Remove the factory installed exhaust pipe from the blower housing collar. Save the exhaust
pipe bracket and screws for use later. (Fig. 7)
3.
Install the new flex pipe assembly to the
blower housing collar using the bracket and
screws removed in step 2. Make sure the
legs are in the upright position. Secure the
assembly with duct tape. Place the clip on
the end of the flex pipe. (Fig. 8)
Blower
Housing
Collar
Fig. 8
Flex Pipe
Assernbly
Duct
Tape
Screws