Service Manual
COMPONENT ACCESS
18” & 24” ADA Built-In Dishwashers
n
4-19
Removing the Sump Assembly (continued)
7. Remove the three (3) screws that aach the sump to the
tub. See Figure 2.
Remove 3 Screws
Figure 2
8. Remove the sump gasket (not shown) and sump.
9. Remove dishwasher from installaon and lay dishwasher
on its back.
10. Disconnect the thermistor wire harness and turbidity
sensor wire harness. See Figure 3.
Disconnect Harnesses
Figure 3
11. Remove the 2 clamps, sump outlet hose, and inlet hose
from the sump. See Figure 4.
Inlet Hose
Outlet Hose
Figure 4
NOTE: Factory installed hose clamps are not reusable.
When installing a water inlet valve, drain pump assembly,
wash pump assembly, or sump assembly, replace the old
clamps with new screw-type hose clamps provided. The
screw-type hose clamps are available separately.
12. Remove the drain pump from the sump.
13. Remove the inner drain hose from the sump.
Sump - Top View
Figure 5
Sump - Boom View
Outlet
Inlet
Turbidity
Sensor
Thermistor
Drain Pump
Drain Hose