30" (76.2 CM) AND 36" (91.4 CM) RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.
TABLE OF CONTENTS VENT SYSTEM SAFETY.................................................................2 INSTALLATION REQUIREMENTS ................................................4 Tools and Parts ............................................................................4 Location Requirements ................................................................4 Electrical Requirements ...............................................................7 Venting Requirements..........................................
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. ■ Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Parts Supplied Tools Needed ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Jigsaw or keyhole saw Drill ¹⁄₈" (3 mm) drill bit for pilot holes Pencil Tape measure or ruler Flat-blade screwdriver Phillips screwdriver ³⁄₈" (9.
Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 13¹⁄₂" (34.3 cm) retractable vent height 1¹⁄₂" (3.8 cm) ³⁄₈" (0.95 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 5¹⁄₄"(13.3 cm) for 30" (76.2 cm) vent 8¹⁄₄"(21.0 cm) for 36" (91.4 cm) vent 28¹⁄₂" (72.4 cm) 13¹⁄₈" (33.4 cm) ³⁄₄ (1.9 cm) 16¹⁄₂" (42.0 cm) 10" (25.4 cm) 2¹⁄₈" (5.4 cm) Cabinet Dimensions 10" (25.4 cm) A= ¹⁄₂" (12.7 mm) minimum 21⁵⁄₁₆" (54.1 cm) 21⁵⁄₁₆" (54.
Countertop Cutout Dimensions IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations. Some models require a countertop deeper than 25" (63.5 cm); see the following “Countertop Cutout Dimensions Chart.” To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts. See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation details.
Electrical Requirements Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
INSTALLATION INSTRUCTIONS Venting Methods Determine which venting method is best for your application. Vent system can terminate either through the wall or floor. Island Location—Vent System Installed Under a Concrete Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Front (Standard)-Mounted Blower Motor Rear-Mounted Blower Motor B A D E C M F G A A H L K I J Rear Mounted Blower Motor A.
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece Example Vent System C 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Rectangular A 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 90° elbow 5.0 ft (1.5 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) flat elbow 12.0 ft (3.7 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) wall cap 0.0 ft (0.0 m) Vent Piece 6" (15.2 cm) Round 45° elbow 2.5 ft (0.8 m) 6 ft (1.8 m) B 2 ft (0.6 m) D 90° elbow 5.0 ft (1.5 m) 6" (15.
4. Install the right and left undercounter mounting brackets to the vent box. Slide the keyhole slots over the guide tabs and push the brackets up to set them into place. 7. Attach the support legs to the side of the vent box with 4 - 4 x 8 mm screws in each support leg. Adjust to dimension “Y” from the bottom of the vent box to the bottom of the support legs. Tighten screws. B A C C A Dim. “Y” D B A. Vent box B. Undercounter mounting bracket C. Keyhole slots D. Guide tabs 5.
Left or Right Venting: 1. Using two or more people, place the downdraft vent system on its back. 2. Remove the 4 screws from the cover plate mounted to the face of the motor box and set them aside. Rear Mounting—Blower Motor NOTE: Optional blower motor rear mounting position (opposite side) for island cabinet locations. The blower motor box assembly can be moved to the opposite side (rear) of the vent box. 1. Remove 7 screws from the mounting flanges of the blower motor box.
4. Lift the ¼" (6.4 mm) deep cover off the shoulder screws in the keyhole slots and set the cover aside. 5. Remove the screws from the wire mounting plate. Complete Installation NOTE: The downdraft vent system is supplied with a 3¹⁄₄" x 10" (8.3 x 25.4 cm) back draft damper and a 6" (15.2 cm) round vent transition with damper. Refer to “3¹⁄₄" x 10" (8.3 x 25.4 cm) back draft damper” or “6" (15.2 cm) round vent transition with damper,” depending upon the type of venting you are using. 3¹⁄₄" x 10" (8.
2. Remove 4 screws attaching the terminal box cover. 5. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws (not provided) of the appropriate length, mount the brackets to the countertop. IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened. B C A A. Terminal box cover A 3. Determine which direction (front or rear) the home power supply cable will enter the terminal box.
2. Feed the power supply cable through the conduit connector and into the terminal box. F B WARNING C D E Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. A A. Green or green and yellow ground wire B. White wires C. UL listed wire connectors Failure to do so can result in death or electrical shock. 3. Connect the green (or green/yellow) ground wire to the green or yellow/green ground wire using UL listed wire connectors.
Operating Downdraft Vent To Use: 1. Push and hold the button on top of downdraft vent for a few seconds. (This slight delay helps avoid unintentional raising of the vent during cleaning of the cooktop area.) Retractable section of downdraft vent will rise. Blower will begin to vent immediately if blower control knob slider is set to an “On” position. 2. Slide the control slider on the right-hand side of the downdraft vent to adjust the blower motor speed.
WIRING DIAGRAM Y 7 Motor Specifications Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A Motor Resistance BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms BU/BK 9.8 Ohms Y/G S50 1˚ Speed W W 12 W BR BR 8 7 6 5 3 W 1 R BR 2˚ Speed R R 10 R 4 GY 2 GY R 3˚ Speed GY GY BK BK W 4˚ Speed BK BK BU 1 BR BK R GY N.C. N.O. Com BR 1 11 Neutral BU GY R 8 1 N.C. N.O. Com R R 2 BU 9 9 BR N.O. Com BR N.C. 5 2 G 16 W BK Y/G L N GY N.O.
ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance.
WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company.
SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres.
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS SUIVANTES : ■ Utiliser cet appareil uniquement dans les applications envisagées par le fabricant. Pour toute question, contacter le fabricant.
EXIGENCES D’INSTALLATION Outils et pièces Rassembler les outils et pièces nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous.
Dimensions du produit Largeurs de la garniture supérieure: 30" (76,2 cm) 36" (91,4 cm) 13¹⁄₂" (34,3 cm) hauteur de l’évacuation rétractable 1¹⁄₂" (3,8 cm) ³⁄₈" (0,95 cm) 27" (68,6 cm) pour une évacuation de 30" (76,2 cm) 33" (83,8 cm) pour une évacuation de 36" (91,4 cm) 5¹⁄₄" (13,3 cm) pour une évacuation de 30" (76,2 cm) 8¹⁄₄"(21,0 cm) pour une évacuation de 36" (91,4 cm) 28¹⁄₂" (72,4 cm) 13¹⁄₈" (33,4 cm) ³⁄₄ (1,9 cm) 16¹⁄₂" (42,0 cm) 10" (25,4 cm) 2¹⁄₈" (5,4 cm) Dimensions du placard 10" (25,4 cm)
Plan de travail—Dimensions des ouvertures à découper IMPORTANT : Les plans de travail avec rebord avant arrondi ne sont pas recommandés pour ces installations. Certains modèles nécessitent un plan de travail de plus de 25" (63,5 cm); voir le tableau des dimensions de l’ouverture du plan de travail. Pour éviter une erreur, avant de découper une ouverture, tracer le périmètre de la table de cuisson et des ouvertures à découper sur le plan de travail.
Spécifications électriques Observer les dispositions de tous les codes et règlements en vigueur. S'assurer que l’installation électrique est correcte et qu'elle satisfait aux exigences de la plus récente édition de la norme National Electrical Code, ANSI/NFPA 70, ou de la norme CSA C22. 1-94, Code canadien de l’électricité, partie 1 et C22.2 No 0M91 (dernière édition) et de tous les codes et règlements en vigueur.
INSTRUCTIONS D'INSTALLATION Méthodes d’évacuation Déterminer la méthode d’évacuation la plus appropriée. La sortie à l’extérieur du circuit d’évacuation peut se faire à travers le plancher ou à travers un mur.
Pour calculer la longueur effective du circuit d’évacuation nécessaire, additionner les longueurs équivalentes (en pieds ou mètres) de tous les composants utilisés dans le circuit. Composant Rectangulaire de 3¹⁄₄" x 10" (8,3 cm x 25,4 cm) Raccord coudé à 90° de 3¹⁄₄" x 10" (8,3 cm x 25,4 cm) 5,0 pi (1,5 m) Exemple de circuit d’évacuation C 6 pi (1,8 m) B A 2 pi (0,6 m) D Coude plat de 3¹⁄₄" x 10" (8,3 cm x 25,4 cm) A. Moteur du ventilateur B. Raccord de transition C. Coudes à 90° D.
4. Installer sur la caisse du système d’extraction les équerres droite et gauche de montage sous le plan de travail. Insérer les encoches en trou de serrure dans les languettes guides et pousser les équerres vers le haut pour les fixer. 7. Fixer les pieds de soutien aux côtés de la caisse du système d’extraction avec 4 vis de 4 x 8 mm pour chacun. Les régler à la distance “Y” entre le bas de la caisse du système d’extraction et le bas des pieds de soutien. Serrer les vis. B A C A C Dim. “Y” D B A.
Sortie par le côté gauche ou le côté droit : 1. À deux personnes ou plus, poser l’arrière du système d’extraction par le bas face au sol. 2. Retirer les 4 vis du couvercle monté à l’avant de la caisse du moteur et les mettre de côté. Montage du ventilateur à l'arrière REMARQUE : Position de montage du ventilateur à l’arrière (côté opposé) possible pour les configurations en îlot. On peut déplacer la caisse du moteur du ventilateur du côté opposé (arrière) de la caisse du système d’extraction. 1.
4. Lever le couvercle d’épaisseur ¹⁄₄" (6,4 mm) pour le sortir des vis à épaulement dans les encoches en trou de serrure et le mettre de côté. 5. Retirer les vis de la platine de montage du câble. Achever l’installation REMARQUE : Le système d’extraction par le bas est livré avec un clapet anti-retour de 3¹⁄₄" x 10" (8,3 x 25,4 cm) et un raccord de transition pour conduit rond de 6" (15,2 cm) avec clapet.
2. Ôter les 4 vis du couvercle du boîtier de connexion. 5. Percer 2 avant-trous à travers les équerres de fixation sous le plan de travail, dans la face inférieure du plan de travail. Avec 2 vis (non fournies) de la longueur adéquate, fixer les équerres au plan de travail. IMPORTANT : Choisir des vis d’une longueur adéquate pour ne pas traverser le plan de travail au serrage. B C A A. Couvercle du boîtier de connexion A 3.
2. Faire passer le câble d’alimentation à travers le connecteur de conduit et dans le boîtier de connexion. F B AVERTISSEMENT C D E Risque de choc électrique Relier le ventilateur à la terre. Brancher le fil relié à la terre au fil vert et jaune relié à la terre dans la boîte de la borne. Le non-respect de ces instructions peut causer un décès ou un choc électrique. 3.
■ Pour les tables de cuisson à gaz dotées du système de rallumage par détection de flamme, le système d'extraction rétractable pourrait disperser la flamme et l'éloigner de l'allumeur à étincelles, ce qui pourrait pousser ce dernier à jeter des étincelles continuellement afin d'essayer de rallumer un brûleur qui est déjà allumé.
SCHÉMA DE CÂBLAGE 7 Caractéristiques du moteur Alimentation 120 VCA Fréquence 60 Hz Puissance nominale 420 W Intensité 3,7 A Résistance du moteur BU/BL 21,6 ohms BU/R 18 ohms BU/GRIS 14,3 ohms BU/N 9,8 ohms JA/VE S50 MAR MAR GRIS MAR R N.O. Com MAR 5 N.F. BL N JA/VE Terre L NEU N.O.
ASSISTANCE OU SERVICE Lors d’un appel pour assistance ou service, veuillez connaître la date d’achat, le numéro de modèle et le numéro de série complets de l’appareil. Ces renseignements nous aideront à mieux répondre à votre demande. Si vous avez besoin de pièces de rechange Les pièces spécifiées par l’usine conviendront et fonctionneront bien parce qu’elles sont fabriquées avec la même précision utilisée dans la fabrication de chaque nouvel appareil.
GARANTIE DES GROS APPAREILS MÉNAGERS WHIRLPOOL CORPORATION GARANTIE LIMITÉE Pendant un an à compter de la date d'achat, lorsque ce gros appareil ménager est utilisé et entretenu conformément aux instructions jointes à ou fournies avec le produit, Whirlpool Corporation ou Whirlpool Canada LP (ci-après désignées “Whirlpool”) paiera pour les pièces spécifiées par l'usine et la main-d'œuvre pour corriger les vices de matériaux ou de fabrication.
LI3ZUB/W10342491C © 2011. All rights reserved. Tous droits réservés.