30" (76.2 CM) AND 36" (91.4 CM) RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM Installation Instructions and Use and Care Guide For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-253-1301 or visit our website at www.whirlpool.com. In Canada, call: 1-800-807-6777, or visit our website at www.whirlpool.ca.
TABLE OF CONTENTS TABLE DES MATIÈRES TABLE OF CONTENTS....................................................................2 TABLE DES MATIÈRES...................................................................2 VENT SYSTEM SAFETY.................................................................3 INSTALLATION REQUIREMENTS..................................................5 Tools and Parts..............................................................................5 Location Requirements.....................
VENT SYSTEM SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.
IMPORTANT SAFETY INSTRUCTIONS Ducted fans must always be vented to the outdoors. For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed ■ Jigsaw or keyhole saw ■ Drill ■ 1/8" (3 mm) drill bit for pilot holes ■ Pencil ■ Tape measure or ruler ■ Flat-blade screwdriver ■ Phillips screwdriver ■ 3/8" (9.
Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 13¹⁄₂" (34.3 cm) retractable vent height 1¹⁄₂" (3.8 cm) 3/8" (9.5 mm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 5¹⁄₄"(13.3 cm) for 30" (76.2 cm) vent 8¹⁄₄" (21.0 cm) for 36" (91.4 cm) vent 28¹⁄₂" (72.4 cm) 13¹⁄₈" (33.4 cm) 3/4" (19 mm) 16¹⁄₂" (42.0 cm) 10" (25.4 cm) 2¹⁄₈" (5.4 cm) Reversed Blower As-Received Blower Front of Range Hood 10" (25.4 cm) Front of Range Hood 51⁄₄" (13.4 cm) 10" (25.
Cabinet Dimensions Countertop Cutout Dimensions 10" (25.4 cm) A = 1/2" (12.7 mm) minimum 21⁵⁄₁₆" (54.1 cm) 21⁵⁄₁₆" (54.1 cm) IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations. Some models require a countertop deeper than 25" (63.5 cm); see the following illustrations. To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.
Electrical Requirements Venting Requirements Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition) or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
INSTALLATION INSTRUCTIONS Venting Methods Island Location — Vent System Installed Under a Concrete Slab Using PVC Sewer Pipe Determine which venting method is best for your application. Vent system can terminate either through the wall or floor. Front-Mounted Blower Motor (Standard) Island Location Front-Mounted Blower Motor (Standard) B Rear-Mounted Blower Motor A D C M H L A A F K E G I J Rear-Mounted Blower Motor A.
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece 31/4" x 10" (8.3 cm x 25.4 cm) Rectangular 31/4" x 10" (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m) Example Vent System C Vent Piece 6" (15.2 cm) Round 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) B A 2 ft (0.6 m) 31/4" x 10" (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m) 31/4" x 10" (8.3 cm x 25.4 cm) 0.0 ft wall cap (0.0 m) 6 ft (1.8 m) D A. Blower motor B.
5. Attach the support legs to the side of the vent box with four 4 x 8 mm screws in each support leg. Adjust to dimension “Y” from the bottom of the vent box to the bottom of the support legs. Tighten screws. Left or Right Venting: 1. Using two or more people, place the downdraft vent system on its back. 2. Remove the four screws from the cover plate mounted to the face of the motor box and set them aside. C A Dim. “Y” B A. Motor box B. Support leg C.
Rear Mounting — Blower Motor NOTE: Optional blower motor rear-mounting position (opposite side) for island cabinet location. The blower motor box assembly can be moved to the opposite side (rear) of the vent box. 1. Remove seven screws from the mounting flanges of the blower motor box. Rear View Front View A A C B A A C A. Screws (6) B. Keyhole slot shoulder screws (2) C. 1/4" (6.4 mm) deep cover B A. Screws (7) B. Keyhole slot shoulder screws (2) C. Blower motor box A A. Deep cover A 4.
6. Hold the wire-mounting plate and push the grommet out of the wire-mounting plate. A 14. Remove the front cover from the deep cover, place the front cover over the previously mounted cover box, and secure using the four screws previously removed. B A. Wire-mounting plate B. Grommet 7. Slide the wire assembly through the slot in the wire-mounting plate to remove it. 8. Place the wire assembly through the opening to the opposite side of the vent box. 9.
Complete Installation NOTE: The downdraft vent system is supplied with a 31/4" x 10" (8.3 cm x 25.4 cm) backdraft damper and a 6" (15.2 cm) round vent transition with damper. Refer to “31/4" x 10" (8.3 cm x 25.4 cm) Backdraft Damper” or “6" (15.2 cm) Round Vent Transition with Damper,” depending upon the type of venting you are using. 2. Remove four screws attaching the terminal box cover. 31/4" x 10" (8.3 cm x 25.4 cm) Backdraft Damper 1. Attach the 3¼" x 10" (8.3 cm x 25.
5. Install the left and right undercounter mounting brackets to the vent box. Slide the keyhole slots over the guide tabs and push the brackets up to set them in place. 7. Check that the downdraft vent is level as shown below. Loosen the lower support leg screws and position the legs against the cabinet floor. B B A C A D A. B. C. D. Vent box Undercounter mounting bracket Keyhole slots Guide tabs B 6.
Make Electrical Connections WARNING Electrical Shock Hazard Check Operation 1. Push and hold the button on the top of the downdraft vent for a few seconds. The retractable section of the downdraft vent will rise and the blower will be able to start using the control slider. Remove any protective film and use a stainless steel cleaner to clean any remaining grease. Position the top trim over the retractable section and snap trim into place.
VENT SYSTEM USE The retractable downdraft vent system is designed to remove smoke, cooking vapors, and odors from the cooktop area. ■ For best results, the vent should be operating before cooking is started. ■ If you use large or tall utensils, place them on the large rear element or burner surface. ■ A higher heat setting than normally used may be needed when the downdraft vent is operating. ■ For gas cooktops, the downdraft vent system may affect the flame stability and cooking performance.
TROUBLESHOOTING First try the solutions suggested here. If you need further assistance or more recommendations that may help you avoid a service call, refer to the warranty or visit producthelp.whirlpool.com. In Canada, visit http://www.whirlpool.ca. Contact us by mail with any questions or concerns at the address below: In the U.S.A.: In Canada: Whirlpool Brand Home Appliances Customer eXperience Centre Customer eXperience Center Whirlpool Canada LP 553 Benson Road 200 - 6750 Century Ave.
WIRING DIAGRAM YL 7 M BR 2° Speed 1° Speed WH BK GY Blower Switch operation Contact Function Off 1-3 1st Speed 3-5 2nd Speed 5-7 3rd Speed 8 - 10 4th Speed 10 - 12 8 7 5 WH WH BR BR 1 GY RD BR 1 N.O. COM BR BU BR N.O. COM RD N.C. GY 5 N.C. GY GY 3 N.O. COM N.C. 4 GY BK YL/GN 2 WH 1 GND L N BR RD RD RD WH GY 3 GY 2 BK 1 BU GY BK RD N.C. N.O. COM BR BR BR 1 4 6 BK 8 9 WH GY RD BK BU 11 10 12 1 GY RD N.C. N.O.
ASSISTANCE OR SERVICE If you need service In Canada Please refer to the warranty. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance. To locate factory specified replacement parts in your area, call the following customer assistance telephone number or your nearest designated service center.
SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres.
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES, RESPECTER LES INSTRUCTIONS SUIVANTES : Utiliser cet appareil uniquement selon les modalités d’utilisation prévues par le fabricant. Pour toute question, contacter le fabricant.
EXIGENCES D'INSTALLATION Outils et pièces Rassembler les outils et pièces nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous.
Dimensions du produit Largeurs de la garniture supérieure : 30" (76,2 cm) 36" (91,4 cm) 13¹⁄₂" (34,3 cm) hauteur de l’évacuation rétractable 1¹⁄₂" (3,8 cm) ³⁄₈" (0,95 cm) 27" (68,6 cm) pour une évacuation de 30" (76,2 cm) 33" (83,8 cm) pour une évacuation de 36" (91,4 cm) 5¹⁄₄" (13,3 cm) pour une évacuation de 30" (76,2 cm) 8¹⁄₄" (21,0 cm) pour une évacuation de 36" (91,4 cm) 28¹⁄₂" (72,4 cm) 13¹⁄₈" (33,4 cm) ³⁄₄" (1,9 cm) 16¹⁄₂" (42,0 cm) 10" (25,4 cm) 2¹⁄₈" (5,4 cm) Ventilateur inversé Ventilateur
Dimensions du placard Dimensions des ouvertures à découper Largeurs de la garniture supérieure : 30" (76,2 cm) 36" (91,4 cm) 13 ¹⁄₂" (34,3 cm) hauteur de l’évacuation rétractable 1 ¹⁄₂" (3,8 cm) 3/8" (9,5 mm) 27" (68,6 cm) pour une évacuation de 30" (76,2 cm) 33" (83,8 cm) pour une évacuation de 36" (91,4 cm) IMPORTANT : Les plans de travail avec rebord avant arrondi ne sont pas recommandés pour ces installations.
B ■ D C Exigences concernant l'évacuation A IMPORTANT : Avant d'effectuer des découpes, s'assurer qu'il y a un dégagement convenable dans le mur ou le plancher pour le système d’extraction. E A. 1/2" (1,3 mm) minimum jusqu’au panneau antiéclaboussure ou mur arrière B. 3/4" (19,1 mm) maximum pour la profondeur du panneau anti-éclaboussure C. 27 1/2" (69,9 cm) sur les modèles de 30" (76,2 cm) 33 1/2" (85,9 cm) sur les modèles de 36" (91,4 cm) D. D = E + 1 13/16" (46,2 mm) E.
INSTRUCTIONS D'INSTALLATION Méthodes d’évacuation Déterminer la méthode d’évacuation la plus appropriée. La sortie à l’extérieur du circuit d’évacuation peut se faire à travers le plancher ou à travers un mur.
Calcul de la longueur effective du circuit d’évacuation Un conduit rectangulaire de 3¼" x 10" (8,3 cm x 25,4 cm) est nécessaire pour la caisse du ventilateur. Il peut être raccordé à un conduit rond de 6" (15,2 cm) si nécessaire. Exemple de circuit d’évacuation C 6 pi (1,8 m) B A Longueur maximum du circuit d’évacuation Conduit d’évacuation Longueur Conduit dia.
5. Fixer les pieds de soutien aux côtés de la caisse du système d’extraction avec quatre vis de 4 x 8 mm pour chacun. Les régler à la distance “Y” entre le bas de la caisse du système d’extraction et le bas des pieds de soutien. Serrer les vis. Sortie par le côté gauche ou le côté droit : 1. À deux personnes ou plus, poser l’arrière du système d’extraction par le bas face au sol. 2. Retirer les quatre vis du couvercle monté à l’avant de la caisse du moteur et les mettre de côté. C A Dim. “Y” B A.
Montage du ventilateur à l'arrière REMARQUE : Position de montage du ventilateur à l’arrière (côté opposé) possible pour les configurations en îlot. On peut déplacer la caisse du moteur du ventilateur du côté opposé (arrière) de la caisse du système d’extraction. 1. Ôter les sept vis des rebords de montage de la caisse du ventilateur. Vue arrière Vue de face A A C B A A C A. Vis (6) B. Vis à épaulement pour encoches en trou de serrure (2) C. Couvercle d’épaisseur 1/4" (6,4 mm) B A. Vis (7) B.
6. En maintenant la platine de montage du câble, sortir l’œillet. A 13. Monter le couvercle de 5 1/4" (13,4 cm) (fourni) à l’avant de la caisse du système d’extraction. Placer les encoches en trou de serrure par-dessus les 2 vis à épaulement, aligner les trous de montage et fixer le couvercle à la caisse du système d’extraction à l’aide des six vis précédemment retirées du couvercle d’épaisseur 1/4" (6,4 mm). 14.
Achever l’installation REMARQUE : Le système d’extraction par le bas est livré avec un clapet anti-retour de 3 1/4" x 10" (8,3 cm x 25,4 cm) et un raccord de transition pour conduit rond de 6" (15,2 cm) avec clapet. Se reporter à la section “Clapet anti-retour de 3 1/4" x 10" (8,3 cm x 25,4 cm)” ou “Raccord de transition pour conduit rond de 6" (15,2 cm) avec clapet”, selon le type de circuit d’évacuation utilisé. 2. Ôter les quatre vis du couvercle du boîtier de connexion.
5. Fixer les brides de montage pour le dessous du plan de travail sur le conduit d’évacuation. Faire glisser les encoches en trou de serrure sur les guides, puis pousser les brides vers le haut pour les mettre en place. 7. Vérifier que le système d’extraction par le bas est d’aplomb vertical comme illustré. Desserrer les vis des pieds de soutien inférieurs et régler les pieds de soutien en appui sur le plancher du placard. B B A C A D A. B. C. D.
Raccordements électriques AVERTISSEMENT 5. Raccorder les deux conducteurs noirs avec des connecteurs de fils (homologation UL). 6. Réinstaller le couvercle du boîtier de connexion et le fixer avec la vis. 7. Reconnecter la source de courant électrique. Contrôle du fonctionnement Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche.
UTILISATION DU SYSTÈME D’EXTRACTION Le système d’extraction par le bas rétractable sert à éliminer la fumée, les vapeurs de cuisson et les odeurs issues de la table de cuisson. ■ Pour de meilleurs résultats, le système d’extraction doit être en marche avant d'entreprendre une cuisson. ■ Lors de l’emploi d’un récipient de grande taille, le placer sur le grand brûleur ou élément chauffant à l’arrière.
ENTRETIEN DU SYSTÈME D’ÉVACUATION Surface du système d’extraction par le bas Pour éviter d’endommager la finition, nettoyer les surfaces avec de l’eau savonneuse. Ne pas utiliser une solution de récurage ou un produit abrasif. Surfaces externes : Afin d’éviter d’endommager la surface externe, ne pas utiliser de tampons en laine d’acier ou de tampons à récurer savonneux. Toujours essuyer pour éviter de laisser des marques d’eau. Méthode de nettoyage : ■ Nettoyage : 1.
DÉPANNAGE Essayez d’abord les solutions suggérées ici. Pour obtenir de l’aide ou des conseils qui permettront peut-être d’éviter une intervention de dépannage, consulter de garantie ou visiter le site Internet producthelp.whirlpool.com. Au Canada, visiter le www.whirlpool.ca.
SCHÉMA DE CÂBLAGE 7 M BL 11 R BL 1 MAR MAR R GRIS MAR MAR R 9 10 12 R BL 4 GRI S 3 GRIS 2 N 1 6 N R BL GRIS N BU BU N N.C. N.O. COM MAR 1 8 7 2° Vitesse 1° Vitesse BL 3° Vitesse R N Fonctionnement du commutateur du ventilateur Contact Fonction 1-3 Arrêt 3-5 1ére Vitesse 5-7 2e Vitesse 3e Vitesse 8 - 10 10 - 12 4e Vitesse 1 GRIS R N.C. N.O.
ASSISTANCE OU SERVICE Si vous avez besoin de service Au Canada Consultez la garantie du présent manuel. Si vous avez besoin de pièces de rechange Si vous avez besoin de commander des pièces de rechange, nous vous recommandons d'utiliser seulement des pièces spécifiées par l'usine. Les pièces spécifiées par l'usine conviendront et fonctionneront bien car elles sont fabriquées avec la même précision que celles utilisées pour fabriquer chaque nouvel appareil.
/™ ©2021 Whirlpool. All rights reserved. Used under license in Canada. Tous droits réservés. Utilisé sous licence au Canada.