Owner's Manual

4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation.Read and follow the instructions provided
withanytools listed here.
Tools needed
Parts supplied
Remove parts from package. Check that all parts are included.
Parts needed
For 7" (17.8 cm) round vented installations
Optional accessories
* For information on ordering, see the “Assistance or Service”
section.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation
clearances specied on the model/serial/rating plate.
Themodel/serial/rating plate is located inside the range
hoodon the left wall.
Range hood location should be away from strong draft
areas,such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be
used.Given dimensions provide minimum clearance.
Consultthe cooktop/range manufacturer installation
instructions before making any cutouts.
This range hood is recommended for use with cooktops
witha maximum total rating of 40,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
All openings in ceiling and wall where range hood will
beinstalled must be sealed.
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal lters. See the “Assistance or
Service” section for information on ordering charcoal lters.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD, Part 280),
or whensuch standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A
orlatest edition, or with local codes.
Product Dimensions
Caulking gun and weatherproof
caulking compound
Jigsaw or keyhole saw
Flat-blade
screwdriver
Drill with 1/8"
(3 mm), 1/2"
(13 mm)
and 1¹⁄₄"
(3 cm) bits
Wire stripper
#2 Phillips
screwdriver
Metal snips
Pencil
#8-18 x 5/8"
(4.2 x 16 mm)
truss-head screws
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Mounting
brackets
7" (17.8 cm) round vent
mounting plate
Part Number W10388168*
UL listed/CSA
approved
wire connectors
120 V, 75 W
maximum,
type E26
lamp
UL listed/CSA
approved 1/2
(13 mm) strain relief
7" (17.8 cm) round
metal vent system with
wall or roof cap
7" (17.8 cm)
round damper
Part Number
W10355451*
Vent clamps as
required
Power
cord kit
Part Number
W10355452*
Stainless steel cleaner
and polish
Part Number 31462A*
1"
(2.5 cm)
4¹⁵⁄₁₆"
(12.5 cm)
6⁹⁄₁₆" (16.7 cm)
29¹⁵⁄₁₆" (76.0 cm)
18⁵⁄₈"
(47.3 cm)
1¹⁄₂"
(3.8 cm)
9"
(22.9 cm)
2"
(5.1 cm)
1"
(2.5 cm)