Installation Instructions

24
Make Electrical Connection
Connect Range Hood and In-Line Smart Kit
1. Install the UL listed or CSA approved strain reliefs (3) in the
range hood and In-Line Smart Kit electrical knockouts.
2. Measure the distance between the In-Line Smart Kit and the
range hood terminal box.
3. Install 8 - 14 AWG wires with an insulating sleeve or conduit
between the terminal box and UL listed strain reliefs.
4. Connect together the set of 8 wires in the In-Line Smart Kit
terminal box.
5. Connect together the set of 8 wires in the range hood
terminal box.
Connect In-Line Smart Kit
Electrical Connection In-Line Smart Kit
1. Use a UL listed or CSA approved wire connector to connect
the black wires together.
2. Use a UL listed or CSA approved wire connector to connect
the white wires together.
3. Use a UL listed or CSA approved wire connector to connect
the red wires together.
4. Use a UL listed or CSA approved wire connector to connect
the blue wires together.
5. Use a UL listed or CSA approved wire connector to connect
the gray wires together.
6. Use a UL listed or CSA approved wire connector to connect
the brown wires together.
7. Use a UL listed or CSA approved wire connector to connect
the yellow wires together.
8. Use a UL listed or CSA approved wire connector to connect
the green/yellow wires together.
9. Tighten the UL listed or CSA approved strain relief.
Electrical Connection Range Hood
10. Repeat all steps above to make the electrical connection in
the range hood terminal box.
11. Connect power supply wires together using the “Make
Electrical Connections” section in the range hood manual.
12. Reinstall the terminal box cover on the In-Line Smart Kit and
reinstall the electrical box cover on the range hood.
13. Reconnect power.
A. Distance between in-line smart kit
and the range hood terminal box
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.