Installation Instructions

4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools needed
Drill
1¼" (3.0 cm) drill bit
¹⁄₈" (3.0 mm) drill bit
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Metal duct tape
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
10" (25.4 mm) driver extension
Parts needed
½" (13 mm) UL listed or CSA approved wiring conduit and
connector. The length of the conduit is determined by the
distance between the In-Line Smart Kit and the range hood.
8 - 14 AWG wires, one of each of the following colors:
black, white, red, blue, gray, brown, yellow and green/yellow
(ground). The lengths of the wires are determined by the
distance between the In-Line Smart Kit and the range hood.
3 - UL listed strain relief ½" (13 mm)
6" (15.2 cm) round vent duct
Parts supplied
Remove parts from packages. Check that all parts are included.
1 - 6" (15.5 cm) vent transition without backdraft damper
1 - 6" (15.5 cm) vent transition with backdraft damper
4 - 3.5 x 6.5 mm mounting screws
4 - 3.5 x 9.5 mm mounting screws
1 - 9-pin pigtail electrical connector with 8 wire pigtail
1 - Metal terminal box and cover
16 - UL listed or CSA approved wire connectors
1 - T10 Torx
®†
adapter
1 - T20
®
Torx
®
adapter
1 - Plastic wire clip
4 - 5 x 45 mm mounting screws
3 - 2.9 x 13 mm mounting screws
1 - UL listed or CSA approved plastic strain reliefs
1 - in-line housing
1 - in-line base
1 - in-line mounting bracket
1 - Cover plate
1 - UL listed or CSA approved wire clamp
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Have
a qualified technician install the In-Line Smart Kit.
All openings in the ceiling and wall where the In-Line Smart Kit
will be installed must be sealed.
For Mobile Home Installations
The installation of this in-line blower system must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
6"
(15.2 cm)
4" (10.2 cm)
10¹¹⁄₁₆"
(27.1 cm)
4" (10.2 cm)
6" (15.2 cm)
9⁵⁄₈"
(24.5 cm)
26" (66.0 cm)
12"
(30.5 cm)