Use and Care Manual

13
5. If the burner grates are installed, remove them.
Use the following chart to match the correct gas orifice spud
with the burner location and model being converted.
Propane Gas Orifice Spud Chart
Model
Family
Burner
Burner
Rating
(BTU)
Color
Stamp
(A)
Size
(mm)
WCG-
K3030P,
WCG-
K5030P
Right
Front
6500 BLACK 80 0.8
Left
Front
11000 GREEN 100 1
Right
Rear
11000 GREEN 100 1
Left
Rear
4000 RED 60 0.6
Center N/A N/A N/A N/A
WCG-
K5036P,
WCG-
K7030P,
WCG-
K7530P,
WCG-
K7536P
Right
Front
6500 BLACK 80 0.8
Left
Front
11000 GREEN 100 1
Right
Rear
6500 BLACK 80 0.8
Left
Rear
4000 RED 60 0.6
Center 11000 GREEN 100 1
WCG-
K7036P
Right
Front
9000 YELLOW 90 0.9
Left
Front
11000 GREEN 100 1
Right
Rear
9000 YELLOW 90 0.9
Left
Rear
4000 RED 60 0.6
Center 11000 GREEN 100 1
A
A. Stamp
Burner Locations
A. Left front
B. Left rear
C. Center
D. Right rear
E. Right front
6. Remove all burner caps and burner bases (see the Quick
Start Guide for burner reference).
B
D
C
A
Standard Flame
A.
Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
7. To Convert Standard Burner:
Use 7.0 mm wrench to loosen and remove the orifice
spud (A).
Set gas orifice spud aside.
Replace with correct Propane gas orifice spud. See
Propane gas orifice spud chart.
A
B C
A. Orifice spud
B. Orifice spud holder
C. Spark electrode
8. Replace sheet of insulation.