Service Manual

COMPONENT ACCESS
18” & 24” ADA Built-In Dishwashers
n
4-9
Removing the Nozzle Duct
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Remove the Nozzle Duct
1. Unplug dishwasher or disconnect power.
2. Open the door, and remove the 2 screws on the Lower
spray seat (see Figure 1).
Remove 2 screws
Figure 1
3. Release the snap clips (le side shown in the Figure 2).
Then remove the nozzle duct and lower spray seat.
Figure 2