If your outlet looks like this:
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord
with ring or spade terminals and UL-listed
strain relief. The 4-wire power supply cord,
at least 4 ft. (1.22 m) long, must have four
10-gauge copper wires and match a 4-wire
receptacle of NEMA Type 14-30 R. The
ground wire (ground conductor) may be
either green or bare. The neutral
conductor must be identified by a white
cover.
If your outlet looks like this:
3-wire receptacle
(10-30R)
Then choose a 3-wire power supply cord
with ring or spade terminals and UL-listed
strain relief. The 3-wire power supply cord,
at least 4 ft. (1.22 m) long, must have three
10-gauge copper wires and match a 3-wire
receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum) at least 5 ft.
(1.52 m) long.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected appliance:
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative if
you are in doubt as to whether the appliance is properly
grounded. Do not modify the plug provided with the
appliance: If it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
For a permanently connected appliance:
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the appliance.
SAVE THESE INSTRUCTIONS
Electric Requirements Canada
WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility:
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association, 178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4-wire, single-phase, 120/240 V, 60 Hz,
AC-only electrical supply on a separate 30 A circuit, fused on
both sides of the line. A time-delay fuse or circuit breaker is
recommended. Connect to an individual branch circuit.
This dryer is equipped with a UL-listed and/or CSA
International Certified Power Cord intended to be plugged into
a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m)
long. Be sure wall receptacle is within reach of dryer’s final
location.
4-wire receptacle (14-30R)
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not use an extension cord.
For further information, or to obtain a Power Supply Cord
Replacement (Part Number W11095079), please reference the
contact information listed on your Quick Start Guide.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected appliance:
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative if
you are in doubt as to whether the appliance is properly
grounded. Do not modify the plug provided with the
appliance: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS