Owners Manual
Table Of Contents
- Dryer Safety
- Dryer Safety
- Dryer Maintenance and Care
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Changing the Drum Light (on some models)
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- Special Instructions for Steam Models
- Installation Instructions
- Requirements
- Tools and Parts
- Location Requirements
- Electrical Requirements – U.S.A.
- Electric Requirements – Canada
- Installation
- Install Leveling Legs
- Electrical Installation – U.S.A.
- Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Inlet Hoses
- Connect Vent (Vented Models Only)
- Level Dryer
- Complete Installation Checklist
- Sécurité de la sécheuse
- Sécurité de la sécheuse
- Entretien et réparation de la sécheuse
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Changement de l’ampoule d’éclairage du tambour (sur certains modèles)
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre lorsque l’appareil n’est pas utilisé, est entreposé ou déménagé
- Instructions spécifiques pour les modèles vapeur
- Instructions d’installation
- Spécifications
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques – É.-U.
- Spécifications électriques – Canada
- L’installation
- Installation des pieds de nivellement
- Installation Électrique - U.S.A
- Exigences concernant l'évacuation
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement des tuyaux d’alimentation
- Raccorder le conduit d’évacuation (sur les modèles avec conduit seulement)
- Réglage de l’aplomb de la sécheuse
- Liste de vérification pour installation terminée
12
3. Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to “4-Wire Power
Supply Cord Connection.” Then, go to
“Venting Requirements.”
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to “3-Wire Power
Supply Cord Connection.” Then, go to
“Venting Requirements.”
4-wire direct connection: Go to “Direct Wire
Strain Relief,” then “4-Wire Direct Wire
Connection,” then, go to “Venting
Requirements.”
3-wire direct connection: Go to “Direct Wire
Strain Relief”, then “3-Wire Direct Wire
Connection,” then, go to “Venting
Requirements.”
NOTE: If local codes do not permit connection of a cabinet-
ground conductor to neutral wire, go to “Optional 3-wire
Connection.” This connection may be used with either a
power supply cord or a direct wire connection.
Power Supply Cord Connection
Power Supply Cord Strain Relief
1. Attach power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL-listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
2. Attach power supply cord to strain relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
4-Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL-listed strain relief
G. Ring terminals
3. Prepare to connect neutral ground wire and
neutral wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from green external ground conductor screw
(A).