Owners Manual
Table Of Contents
- Dryer Safety
- Dryer Safety
- Dryer Maintenance and Care
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Changing the Drum Light (on some models)
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- Special Instructions for Steam Models
- Installation Instructions
- Requirements
- Tools and Parts
- Location Requirements
- Electrical Requirements – U.S.A.
- Electric Requirements – Canada
- Installation
- Install Leveling Legs
- Electrical Installation – U.S.A.
- Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Inlet Hoses
- Connect Vent (Vented Models Only)
- Level Dryer
- Complete Installation Checklist
- Sécurité de la sécheuse
- Sécurité de la sécheuse
- Entretien et réparation de la sécheuse
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Changement de l’ampoule d’éclairage du tambour (sur certains modèles)
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre lorsque l’appareil n’est pas utilisé, est entreposé ou déménagé
- Instructions spécifiques pour les modèles vapeur
- Instructions d’installation
- Spécifications
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques – É.-U.
- Spécifications électriques – Canada
- L’installation
- Installation des pieds de nivellement
- Installation Électrique - U.S.A
- Exigences concernant l'évacuation
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement des tuyaux d’alimentation
- Raccorder le conduit d’évacuation (sur les modèles avec conduit seulement)
- Réglage de l’aplomb de la sécheuse
- Liste de vérification pour installation terminée
15
5. Connect neutral ground wire and neutral wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
6. Connect ground wire
Connect ground wire (green or bare) (F) of direct wire cable
under green external ground conductor screw (A). Tighten
screw.
7. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Insert tab of
terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw. Now, go to “Venting
Requirements.”
3-Wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting cabinet-
ground conductor to neutral wire.
3. Prepare your 3-wire cable for direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3 1/2" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
4. Remove center screw
Remove center terminal block screw (B).
5. Connect neutral wire
Place hooked end of neutral wire (white or center) (C) of
direct wire cable under center terminal block screw (B).
Squeeze hooked end together. Tighten screw.