Owners Manual
Table Of Contents
- DRYER SAFETY
- Dryer Safety
- DRYER MAINTENANCE AND CARE
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Changing the Drum Light (on some models)
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements – U.S.A.
- Electric Requirements – Canada
- INSTALLATION
- Install Leveling Legs
- Electrical Installation – U.S.A.
- Home Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Inlet Hoses
- Connect Vent (Vented Models Only)
- Level Dryer
- Complete Installation Checklist
- SECURITE DE LA SECHEUSE
- Sécurité de la sécheuse
- ENTRETIEN ET REPARATION DE LA SECHEUSE
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Changement de l’ampoule d’éclairage du tambour (sur certains modèles)
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre avant une non-utilisation, un entreposage ou un déménagement
- INSTRUCTIONS D'INSTALLATION
- SPECIFICATIONS
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques – É.-U.
- Spécifications électriques – Canada
- INSTALLATION
- Installation des pieds de réglage de l’aplomb
- Installation électrique – É.-U.
- Exigences concernant l’évacuation pour une maison
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement des tuyaux d’alimentation
- Raccordement du conduit d’évacuation (sur les modèles avec conduit seulement)
- Réglage de l’aplomb de la sécheuse
- Blank Page
- Blank Page
- Blank Page
- Blank Page
20
Connect Vent (Vented Models Only)
1. Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure vent is clean.
Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2. Move dryer to final location
Move dryer to final location. Avoid crushing or kinking the
vent. After dryer is in place, remove corner posts and
cardboard from under dryer.
Level Dryer
1. Level Dryer
Check levelness of dryer from side to side. Repeat from front
to back.
NOTE: The dryer must be level for the moisture-sensing
system to operate correctly.
2. Adjust leveling legs
If dryer is not level, prop up using a wood block. Use wrench
to adjust legs up or down, and check again for levelness.
Once dryer is level, make sure all four legs are snug against
the floor and the dryer does not rock.
3. Install and remove base trim (on some models)
To Install: Place the skirt to bottom of dryer and match the
locating pins with the holes. Press the skirt firmly upwards
until it snaps into place.
To Remove: On each corner, push down on top of base trim.
Rotate away from dryer and remove.