Troubleshooting guide

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
PAGE 13
TEST #4a Thermistors
Outlet Thermistor
The machine control electronics monitors the
exhaust temperature using the outlet thermistor,
and cycles the heater relay on and off to maintain
the desired temperature.
Begin with an empty dryer and a clean lint
screen.
1. Plug in dryer or reconnect power.
2. Start theTimed Dry cycle.
3. If after 60 seconds, f:22 or f:23 shows in
the display and the dryer shuts off,the thermistor
or wire harness is either open or shorted.
Unplug dryer or disconnect power.
Check wire connections at the machine control
electronics and thermistor. See Accessing &
Removing the ElectronicAssemblies, page 17,and
for thermistor location,see figure 10, page 12.
If wire connections are OK, check the outlet
thermistor resistance per step 5.
4. If f:22 or f:23 does not show in the display,
the connections to the thermistor are good.
Therefore,check the exhaust temperature value
at any or all of the temperature levels in question,
using the Timed Dry cycle,and the following
process:
Hold a glass bulb thermometer capable of
reading from 90° to 18F (32° to 82°C) in the
center of the exhaust outlet.The correct exhaust
temperatures are as follows:
EXHAUST TEMPERATURES
Temperature HeatTurns Off* HeatTurns On
Setting °F C) °F C)
High 155°± (68°±) 1015° (68°)
Medium 14±5° (6±3°) below the
Low 12±5° (5±3°) heat turn off
Extra Low 11±5° (4±3°) temperature
* The measured overshoot using the glass bulb
thermometer in the exhaust outlet can be 30°F
(1C) higher.
5. If the exhaust temperature is not within
specified limits, or you have come here from
step 3,perform the following:
NOTE: All thermistor resistance measurements
must be made while dryer is unplugged or
disconnected from power.
Remove the P14 connector, then measure the
resistance between P14-3 (red wire) and P14-6
(red wire) at the connector.
If the resistance is OK,check P14-3 and P14-6
to dryer ground.
If resistance is greater than 0 (zero),replace
wiring harness.
The following table gives temperatures and their
associated resistance values.
OUTLET THERMISTOR RESISTANCE
Res. Res.
Temp Range Temp Range
°F C) °F C)
50° (1) 19.0–22.0 80° (2) 8.5–10.5
60° (1) 14.8–16.8 90° (3) 6.8–8.8
70° (2) 11.5–13.5 100° (3) 5.0–7.0
If the thermistor resistance does not agree
with table,replace the outlet thermistor.
If the thermistor resistance checks agree
with the measurements in the table, replace
the machine control electronics.