Installation Instruction

13
1. Prepare to connect neutral bond
wire and neutral wire
Remove center terminal block screw (B). Remove neutral bond
wire (E) from green external ground conductor screw (A).
2. Connect neutral bond wire
and neutral wire
Connect neutral bond wire (E) and neutral wire (white or center)
(C) of power supply cord under center terminal block screw (B).
Tighten screw.
3. Connect ground wire
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten screw.
A
B
E
B
E
C
A
F
1. Remove center screw
Remove center terminal block screw (B).
3-wire receptacle
(NEMA type 10-30R)
3 prong plug
Spade terminals
with upturned ends
Ring terminals
4. Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into
slot of dryer rear panel. Secure cover with hold-down screw.
Now go to “Venting Requirements.”
3-Wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B