Installation Instruction

21
CONNECT INLET HOSE
(STEAM MODEL ONLY)
For non-steam models, skip to “Connect Vent.”
The dryer must be connected to the cold water faucet using
the new inlet hoses (not supplied). Do not use old hoses.
NOTE: Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record hose installation or replacement dates on
the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
Turn cold water faucet off and remove washer inlet hose.
Remove old rubber washer from inlet hose and replace with
new rubber washer.
Attach 2 ft (0.6 m) inlet hose to cold water faucet. Screw on
coupling by hand until it is seated on faucet. Then attach “Y”
connector to male end of the 2 ft (0.6 m) inlet hose. Screw on
coupling by hand until it is seated on connector.
Using pliers, tighten the couplings with additional 2/3 turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Attach one of the 5 ft (1.5 m) inlet hose ends to the “Y” connector.
Attach washer cold inlet hose to other side of “Y” connector.
Screw on coupling by hand until it is seated on connector.
Using pliers, tighten the couplings an additional 2/3 turn.
NOTE: Do not overtighten. Damage to the coupling can result.
3. Tighten couplings
4. Attach long hose to “Y” connector
and tighten couplings
1. Turn cold water off, remove hose,
and replace rubber washer
2. Attach short hose and “Y” connector