Troubleshooting guide

PAGE 26
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
COMPONENT LOCATIONS
See Removing Top Panel, page 22, to access:
•UserInterface(UI)
•CycleControlUnit(CCU)
•InletThermistor(Gas)
See Removing Rear Panel,
page 22, to access:
•WaterNozzle
•WaterValve
•ThermalCut-off
•InletThermistor(Electric)
•HighLimitThermostat
•HeaterAssembly
Drum Light
Assembly
Door Switch
(Location may vary
between models.)
See Removing Front Panel
and Bulkhead, page 22, to access:
•MotorAssembly&BeltSwitch
•ThermalFuse
•OutletThermistor
•MoistureSensorStrips
Figure 21 - Component locations.
SPECIFICATIONS
Voltage:
240 VAC (200-260) Elect. Dryer, 2-phase, “optimized”
208 VAC (176-229) Elect. Dryer, 3-phase, “less optimized”
120 VAC (100-130) Gas Dryer
Amps:
(ELECT) 30 Amp Service
(GAS) 15 Amp Service
Frequency: 58 to 62 Hz (60 Hz nominal)
Water Pressure: 20-120 PSI
Operating Temperature Range: 40 to 105°F (5 to 40°C)
Dryer Height: 39 in. (99.1 cm)
Dryer Width: 27 in. (68.6 cm)
Dryer Depth: 31 in. (78.7 cm)
DRYER SPECIFICATIONS
NOTE: Refer to Figure 11b, page 14,
for gas dryer component locations.
1M 2M 3M 5M 6M
=
Contacts
Function
Start
Run
Contacts closed
Black-White
Lt. Blue
Green-Y e llow
Red
Red
Black
Blue
Blue
WHIT E
White
White
Centrifugal Switch (Motor)
Gas Valve, Gas Dryer
Pluggable Drive Motor Switch