Installation Instruction

8
Level Range
1. Place level on the oven bottom, as indicated in one of the
two figures below, depending on the size of the level. Check
with the level side-to-side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
®
Self-Clean Technology.
Electrical Connection - U.S.A. Only
If your home has a 3- or 4-wire receptacle, continue with “Install
Using a Power Supply Cord.” If your home has a 3- or 4-wire
direct connection, go to “Install Using Direct Wire.”
Install Using a Power Supply Cord
Power Supply Cord Strain Relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and out
to remove cover from range.
A. Mounting tabs (3)
B. Lower access cover
C. Screws (2)
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be
connecting to:
Go to Section:
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
minimum,
40- or 50-amp,
range power
supply cord
3-Wire Connection:
Power Supply Cord
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
minimum,
40- or 50-amp,
range power
supply cord
4-Wire Connection:
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A
B
C
A