ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in accordance
with local codes and ordinances, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code,
CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended
that a qualified electrical installer determine that the ground path is
adequate.
A 120-volt, 60-Hz., AC-only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended.
It is recommended that a separate circuit serving only this range be
provided.
Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet
provides 120-volt power and is correctly grounded.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
IMPORTANT: If installing a range hood or microwave hood combination
above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop
surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is
shielded by not less than
1
/
4
" (0.64 cm) flame retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
M
A
B
C
D
E
F
H
I
J
L
K
G
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*.
E. 30" (76.2 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of range to side
wall or other combustible material.
G. The shaded area is recommended for installation of rigid
gas pipe and grounded outlet.
H. 13
1
/
8
" (33.3 cm)
I. 7
11
/
16
" (19.5 cm)
J. 4
13
/
16
" (12.2 cm)
K. 31
1
/
16
" (9.4 cm) or measurement of N, whichever is greater
L. 12" (30.5 cm)
M. Cabinet door or hinges should not extend into the cutout.