Owner's Manual

14
Adjust Leveling Legs
1. If range height adjustment is necessary, use a wrench or pliers
to loosen the four leveling legs. This may be done with the
range on its back or with the range supported on two legs after
the range has been placed back to a standing position.
NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using two
or more people, stand range back up onto the cardboard or
hardboard.
2. Measure the distance from the top of the counter to the floor.
3. Measure the distance from the top of the cooktop to the
bottom of the leveling legs. This distance should be the same.
If it is not, adjust the leveling legs to the correct height. The
leveling legs can be loosened to add up to a maximum of 1"
(2.5 cm). A minimum of 3/16" (5 mm) is needed to engage the
anti-tip bracket.
NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, and then tilt forward
to adjust the rear legs.
4. When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final location, check that the anti-
tip bracket will slide under the range and onto the rear leveling
leg prior to anti-tip bracket installation.
NOTE: If a Trim Kit will be used, the top of the cooktop should
be higher than the counter. See the Installation Instructions
included with the Trim Kit for the correct height.
Level Range
1. Place level on the oven bottom, as indicated in one of the two
figures below, depending on the size of the level. Check with
the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
®
Self-
Clean Technology.
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14ʺ (36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This range is factory-set for use with Natural gas. To use this
range with propane gas, see the “Gas Conversions” section
before connecting this range to the gas supply. Gas conversions
from Natural gas to Propane gas or from Propane gas to Natural
gas must be done by a qualified installer.
Typical flexible connection
1. Apply pipe-joint compound made for use with Propane gas to
the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the other
adapter to the gas shutoff valve. Tighten both adapters, being
certain not to move or turn the gas pressure regulator.
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause a
gas leak. Do not allow the regulator to turn when tightening
fittings.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
[1.3 cm] male pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. 1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe
G. Use pipe-joint compound.
H. Adapter