See page 2-3 to access Fault Code Display Mode.
* If the Sense/Fill LED is ON, the fault code is represented; if
OFF, the error code is represented.
= ON
 FAULT NUMBER ERROR NUMBER
Explanaon & Recommended Procedure
(Status LED names may vary between makes and models)
 
SENSE
FILL
WASH
RINSE
DRAIN
SPIN
DONE
SENSE
FILL
WASH
RINSE
DRAIN
SPIN
DONE
F0E0 - NO FAULT On 8 4 2 1  8 4 2 1
F0E2 - OVERSUDS CONDITION DETECTED F E 2
Fault is displayed when suds prevent the basket from spinning up to speed or the pressure sensor detects rising suds level. The
main control will ush water in aempt to clear suds. If the water ush is unable to correct the problem, this may indicate:
• Not using HE detergent.
• Excessive detergent usage.
• Check pressure hose connecon from tub to pressure sensor. Is hose pinched, kinked, plugged, or leaking air?
• Mechanical fricon on drive mechanism or basket (clothing between basket and tub).
 F E 4
Fault is displayed when washer detects water temperature 105°F (40°C) or higher during rinse cycle.
• Hot water geng in. Make sure inlet hoses are connected correctly.
 F E 4 1
Fault is displayed when an o balance condion is detected.
• Check for weak suspension. Basket should not bounce up and down more than once when pushed.
• Clothing should be distributed evenly when loading.
 F 1 E 1
Indicates a main control fault.
• See TEST #1: Main Control, page 3-5.
 F 1 E 2
Indicates a fault of the motor control secon of the main control.
• See TEST #3b: Drive System – Motor, page 3-10.
 F 2 E 1
One or more keys on the User Interface were actuated for 15 consecuve seconds.
• Fault occurs during Diagnosc Test Mode if a stuck key is detected.
• See TEST #4: Console and Indicators, page 3-12.