2-12
n
27” Stacked Laundry Center
DIAGNOSTICS & TROUBLESHOOTING
For Service Technician Use Only
• No operaon
• No Status LEDs
No power to washer. Check power at outlet, check circuit breakers, fuses, or juncon
box connecons.
Connecon problem between AC
plug and power harness.
Check the AC plug, power harness, and main control for
connuity.
Main control not properly installed
in console.
See TEST #4: Console and Indicators, page 3-12.
Main Control problem. See Test #1: Main Control, page 3-5.
No response when
START buon is
pressed
Lid not closed. Check for interference with lid. Lid must be closed for cycle to
start.
User Interface problem. See TEST #4: Console and Indicators, page 3-12.
Main Control problem. See TEST #1: Main Control, page 3-5.
User Interface problem. See TEST #4: Keys and Encoders, page 3-12.
Main Control problem. See TEST #1: Main Control, page 3-5.
No water supplied to washer. 1. Check water connecons to washer.
2. Verify that hot and cold waster supply is on.
Plugged lter/screen. Check for plugged lter or screen in the water valve or hoses.
Drain hose installaon. Check for proper drain hose installaon.
Valve problem. See TEST #2: Valves, page 3-7.
Main Control problem. See Test #1: Main Control, page 3-5.
Pressure hose. See TEST #5: Water Level, page 3-13.
Valve problem. See TEST #2: Valves, page 3-7.
Washer requires calibraon. Perform washer calibraon on page 2-4.
Onboard pressure transducer. See TEST #5: Water Level, page 3-13.
Main control problem. See TEST #1: Main Control, page 3-5.
Water hose installaon. Make sure inlet hoses are connected properly.
Valve problem. See TEST #2: Valves, page 3-7.
Main control problem. See TEST #1: Main Control, page 3-5.
Some tests will require accessing components. See page 3-3,
for component locaons.
For detailed troubleshoong procedures, refer to
“Troubleshoong Tests” beginning on page 3-5.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Connued on next page . . .