Service Manual
Table Of Contents
- Service Manual - 27" Gas & Electric Stacked Laundry Center, L-95
- Table of Contents
- Section 1 - General Information
- Section 2 - Diagnostics & Troubleshooting
- Diagnostic Guide
- Diagnostic LED-Main Control
- Self Diagnostic Test Modes (Washer)
- Activating the Service Diagnostic Test Modes (Washer)
- Unsuccessful Entry
- Exiting the Service Diagnostic Test Modes (Washer)
- Customer Viewable Fault Codes (Washer)
- Fault/Error Codes Chart (Washer)
- Automatic Test Mode Chart (Washer)
- Manual Test Mode Chart (Washer)
- Washer Troubleshooting Guide
- Dryer Troubleshooting Guide
- Section 3 - Testing - Washer
- Section 4 - Testing - Dryer
- Section 5 - Component Access
- Product Specifications & Warranty Information Sources
DIAGNOSTICS & TROUBLESHOOTING
27” Stacked Laundry Center
n
2-9
For Service Technician Use Only
FAULT NUMBER ERROR NUMBER
Explanaon & Recommended Procedure
(Status LED names may vary between makes and models)
SENSE
FILL
WASH
RINSE
DRAIN
SPIN
DONE
SENSE
FILL
WASH
RINSE
DRAIN
SPIN
DONE
F 8 E 2 1
Fault is displayed when main control senses water level that exceeds the washer’s capacity.
• May signify problem with inlet water valves.
• Check pressure hose connecon from tub to pressure sensor. Is hose pinched, kinked, plugged, or leaking air?
• Onboard pressure transducer fault.
• Check for proper drain hose installaon. Is water siphoning out of the drain hose? Drain hose must not be more than 4.5”
(114 mm) into the drain pipe. Make sure drain hose is not seated into drain pipe, and that there is an air gap for venlaon.
Ensure drain height is between 39” (991 mm) and 8’ (2.4 m) above the oor.
• See TEST #2: Valves, page 3-7 and TEST #5: Water Level, page 3-13.
F 8 E 4 1
Fault is displayed when the hot and cold inlet hoses are reversed.
• Make sure inlet hoses are connected correctly.
• See TEST #2: Valves, page 3-7.
F 8 1 E 1
Fault is displayed when the water level does not change aer the drain pump is on for 10 minutes.
• Is the drain hose or the drain pump clogged? Check tub sump under impeller for obstrucons.
• Is the drain hose height greater than 8’ (2.4 m)?
• Too much detergent.
• Check pressure hose connecon from tub to pressure sensor. Is hose pinched, kinked, plugged, or leaking air?
• Is the pump running? If not, see TEST #6: Drain Pump, page 3-14.