TESTING – DRYER
For Service Technician Use Only
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
TEST #5: Door Switch
1. Unplug dryer or disconnect power.
2. Check wire connecons at the door switch and Start
switch.
3. With the door closed, check connuity between the two
outer pins on the door switch (see Figure 1).
Figure 1 - Door Switch
¾ If there is no connuity, replace the door switch.
4. Reassemble all parts and panels.