Installation Instructions

8
Power Supply Cord
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover from range.
3. Depending on your model, remove the plastic tag holding
three 10-32 hex nuts from the middle post of the terminal
block.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A
B
C
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws
Electrical Connection - U.S.A. Only
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4. Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL Listed strain relief in the opening.
Tighten strain relief screw against the power supply cord.
A. UL Listed strain relief