Service Manual
Table Of Contents
- Smart All-In-One Washer/Dryer
- Table of Contents
- Section 1: General Information
- Washer & Dryer Safety
- Introduction
- Features
- Options
- Accessories
- Control Panel & Features
- Control Panel - Tools
- Load & Go Bulk Dispenser
- Theory of Operation - Dry Cycle
- Product Specifications
- Wiring Diagram & Model/Serial Number Location
- Model & Serial Number Nomenclature
- All-In-One Washer/Dryer Maintenance
- Cleaning the Drain Pump Filter/Draining Residual Water
- How to Manually Open a Locked Door
- Section 2: Diagnostics & Troubleshooting
- Section 3: Component Testing
- Component Testing Safety
- Wiring Diagram
- TEST #1: Appliance Control Unit (ACU) Power Check
- TEST #2: Human-Machine Interface (HMI)
- TEST #3: Motor Circuit
- TEST #4: Door Lock System
- TEST #5: Inlet Valve
- TEST #6: Pressure Switch
- TEST #7: Drain/Recirculation Pump
- TEST #8: Wash Heating Element
- TEST #9: Wash Temperature Sensor
- TEST #10a: Dispenser Sensing
- TEST #10b: Dispenser Metering Pumps
- TEST #11: Supply Connections
- TEST #12a: Dry Heating Element
- TEST #12b: Dry Temperature Sensor
- TEST #13: Dry Fan Motor
- Section 4: Component Access
- Removing the Door Assembly
- Removing the Top Panel
- Replacing the Human-Machine Interface (HMI)
- Removing the Front Panel & Bulkhead
- Removing the Rear Access Panel
- Removing the Inlet Valve Assembly
- Removing the Pressure Switch
- Removing the Metering Pumps
- Removing the Detergent Dispenser
- Removing the Dryer Heating Channel Assembly
- Removing the Condenser Duct Assembly
- Removing the RFI Filter
- Removing the Door Lock Assembly
- Removing the Appliance Control Unit (ACU)
- Removing the Motor Control Unit (MCU)
- Removing the Heater & Thermistor
- Removing the Drain & Recirculation Pumps
- Removing the Direct Drive Motor
- Removing the Tub Assembly
- Section 5: Connectivity
- Product Specifications & Warranty Information Sources
3-2
n
Whirlpool Smart All-In-One Washer & Dryer
COMPONENT TESTING
For Service Technician Use Only
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
n Verify the controls are in the off position so that the appliance does not start when energized.
n Allow enough space to perform the voltage measurements without obstructions.
n Keep other people a safe distance away from the appliance to prevent potential injury.
n Always use the proper testing equipment.
n After voltage measurements, always disconnect power before servicing.
IMPORTANT: Electrostatic Discharge (ESD) Sensitive Electronics
ESD problems are present everywhere. Most people begin to feel an ESD discharge at approximately
3000V. It takes as little as 10V to destroy, damage, or weaken the main control assembly. The new
main control assembly may appear to work well after repair is nished, but a malfunction may occur
at a later date due to ESD stress.
n Use an anti-static wrist strap. Connect wrist strap to green ground connection point or unpainted
metal in the appliance
-OR-
n Touch your nger repeatedly to a green ground connection point or unpainted metal in the
appliance.
n Before removing the part from its package, touch the anti-static bag to a green ground
connection point or unpainted metal in the appliance.
n Avoid touching electronic parts or terminal contacts; handle electronic control assembly by
edges only.
n When repackaging main control assembly in anti-static bag, observe above instructions.
IMPORTANT SAFETY NOTICE — “For Technicians only”
This service data sheet is intended for use by persons having electrical, electronic, and mechanical
experience and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property damage. The
manufacturer or seller cannot be responsible, nor assume any liability for injury or damage of any
kind arising from the use of this data sheet.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in
death or electrical shock.