Service Manual
Table Of Contents
- Smart All-In-One Washer/Dryer
- Table of Contents
- Section 1: General Information
- Washer & Dryer Safety
- Introduction
- Features
- Options
- Accessories
- Control Panel & Features
- Control Panel - Tools
- Load & Go Bulk Dispenser
- Theory of Operation - Dry Cycle
- Product Specifications
- Wiring Diagram & Model/Serial Number Location
- Model & Serial Number Nomenclature
- All-In-One Washer/Dryer Maintenance
- Cleaning the Drain Pump Filter/Draining Residual Water
- How to Manually Open a Locked Door
- Section 2: Diagnostics & Troubleshooting
- Section 3: Component Testing
- Component Testing Safety
- Wiring Diagram
- TEST #1: Appliance Control Unit (ACU) Power Check
- TEST #2: Human-Machine Interface (HMI)
- TEST #3: Motor Circuit
- TEST #4: Door Lock System
- TEST #5: Inlet Valve
- TEST #6: Pressure Switch
- TEST #7: Drain/Recirculation Pump
- TEST #8: Wash Heating Element
- TEST #9: Wash Temperature Sensor
- TEST #10a: Dispenser Sensing
- TEST #10b: Dispenser Metering Pumps
- TEST #11: Supply Connections
- TEST #12a: Dry Heating Element
- TEST #12b: Dry Temperature Sensor
- TEST #13: Dry Fan Motor
- Section 4: Component Access
- Removing the Door Assembly
- Removing the Top Panel
- Replacing the Human-Machine Interface (HMI)
- Removing the Front Panel & Bulkhead
- Removing the Rear Access Panel
- Removing the Inlet Valve Assembly
- Removing the Pressure Switch
- Removing the Metering Pumps
- Removing the Detergent Dispenser
- Removing the Dryer Heating Channel Assembly
- Removing the Condenser Duct Assembly
- Removing the RFI Filter
- Removing the Door Lock Assembly
- Removing the Appliance Control Unit (ACU)
- Removing the Motor Control Unit (MCU)
- Removing the Heater & Thermistor
- Removing the Drain & Recirculation Pumps
- Removing the Direct Drive Motor
- Removing the Tub Assembly
- Section 5: Connectivity
- Product Specifications & Warranty Information Sources
COMPONENT ACCESS
Whirlpool Smart All-In-One Washer & Dryer
n
4-9
Removing the Pressure Switch
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
To Remove the Pressure Switch
1. Unplug washer/dryer or disconnect power.
2. Turn o water supply to washer/dryer.
3. Disconnect cold inlet water hose and remove the drain
hose from the standpipe or laundry tub.
4. Perform the procedures on page 4-3, “Removing the Top
Panel” prior to performing the following steps.
5. The pressure switch is located on the right panel toward
the front.
6. Squeeze the pressure switch mounng clip to remove the
pressure switch from the side panel (see Figure 1).
Press inward on
Mounng Clips
Figure 1
7. Remove the hose from the pressure switch (see Figure 2).
8. Disconnect the pressure switch harness (see Figure
2.) Press the clip away from the harness and slide out
connector.
Remove
Hose
Disconnect
Connector
Hose
Port
Figure 2
9. Reverse procedure to reinstall pressure switch.