Installation Instruction

27
3-wire receptacle
(NEMA-type 10-30R)
3 prong plug
Spade terminals
with upturned ends
Ring terminals
4. Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws and also tighten strain relief screws. Finally,
install terminal box cover and secure with the three screws.
Now, go to “Route Drain Hose.
3-Wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
2. Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws and also tighten strain relief screws. Finally,
install terminal block cover and secure with the three screws.
Now, go to “Route Drain Hose.”
Connect neutral (center) wire (C) of power supply cord
under center terminal block screw (A)
. Tighten screw.
3-Wire Power Supply Cord Strain Relief:
IMPORTANT: Use the strain relief supplied with the washer/dryer.
Attach power supply cord to strain relief
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. Do not further tighten strain relief screws
at this point.
Connect ground wire (D) (green or bare) of power supply
cord under green external ground conductor screw (B).
Tighten screw.
3. Connect ground wire
1. Connect neutral (center) wire
D
B
C