Installation Instructions

25
Electrical Requirements –
Canada Only
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate
and in conformance with the Canadian Electrical Code,
C22.1 – latest edition and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Association, 178 Rexdale Blvd., Toronto, ON
M9W 1R3 CANADA.
To supply the required 4-wire, single-phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30 amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
This washer/dryer is equipped with a CSA
International Certied Power Cord intended
to be plugged into a standard 14-30R wall
receptacle. The cord is 5 ft. (1.5 m) in
length. Be sure wall receptacle is within
reach of washer/dryer’s nal location.
Do not use an extension cord.
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
8579325. For further information, please reference the
“Assistance or Service” section.
Electrical Installation – U.S.A. Only
Remove hold-down screws and terminal block cover.
1. Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA-Type 14-30R):
Go to “Power Supply Cord Connection.”
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to “Power Supply Cord Connection.”
NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
External Ground for 3-Wire Connection.”
2. Remove terminal block cover
Before you start: disconnect power.
4-wire receptacle
(14-30R)