COMPONENT ACCESS
Removing the Inlet Valve Assembly
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
To Remove the Inlet Valve Assembly
1. Unplug washer/dryer or disconnect power.
2. Turn o water supply to washer/dryer.
3. Disconnect cold inlet water hose and remove the drain
hose from the standpipe or laundry tub.
4. Perform the procedures on page 4-3, “Removing the Top
Panel” prior to performing the following steps.
5. Disconnect the inlet valve connector (see Figure 1).
Disconnect
Hoses
Remove
Connector
Hose
Clamps
Figure 1
6. Rotate the valve 90 to disengage from rear panel.
7. Slide the two (2) inlet valve clamps away from the valve
assembly and remove the two hoses (see Figure 1).
Inlet Hose Connecons
The inlet hoses must be connected properly. The gray hose
(to condenser sprayer) connects to the top valve port and the
black hose (to dispenser) connects to the boom valve port.