Specifications

2
GAS FURNACE SAFETY
Recognize this symbol as a safety precaution.
Goodman 1
Hazards or unsafe practices could result in property
damage, product damage, severe personal injury or death.
Hazards or unsafe practices may result in property
damage, product damage, personal injury or death.
WARNING
CAUTION
Goodman 9
Hazards or unsafe practices may result in property
or product damage.
CAUTION
ANSI Box Install G 2009 in Goodman Folder
SAVE THESE INSTRUCTIONS
Use only with type of gas approved for this furnace.
Refer to the furnace rating plate.
Install this furnace only in a location and position
as specified in the “Location Requirements” section
of these instructions.
Provide adequate combustion and ventilation air to
the furnace space as specified in the “Venting
Requirements” section of these instructions.
Adequate clearance must be provided around the
vent-air intake terminals.
Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system
only, as specified in the “Venting Requirements”
section of these instructions.
Never test for gas leaks with an open flame. Use a
commercially available soap solution made
specifically for the detection of leaks to check all
connections, as specified in the “Make Gas
Connections” section of these instructions.
Always install furnace to operate within the furnace’s
intended temperature-rise range with a duct system
which has an external static pressure within the
allowable range, as specified in the “Complete
Installation” section of these instructions. See
furnace rating plate.
IMPORTANT SAFETY INSTRUCTIONS
When a furnace is installed so that supply ducts
carry air circulated by the furnace to areas outside
the space containing the furnace, the return air
shall also be handled by duct(s) sealed to the
furnace casing and terminating outside the space
containing the furnace.
A gas-fired furnace for installation in a residential
garage must be installed as specified in the
“Location Requirements” section of these
instructions.
The furnace shall be installed so the electrical
components are protected from water.
Furnaces for indoor installation on combustible
flooring shall not be installed directly on carpeting,
tile or other combustible material other than wood
flooring.