Product specifications

P
RODUCT
S
PECIFICATIONS
WFD195.02 www.whirlpoolcomfort.com 3
SPECIFICATIONS
WFD19
045S3BX
WFD19
070S3BX
WFD19
070S4CX
WFD19
090S4CX
WFD19
090S5DX
WFD19
115S5DX
Heating Capacity
Natural Gas Input¹ 46,000 69,000 69,000 92,000 92,000 115,000
Natural Gas Output¹ 42,800 64,400 64,400 86,000 86,000 106,500
LP Gas Output¹ 38,502 57,753 57,753 77,004 77,004 96,255
AFUE² 93 93 93 93 93.0 93
Available AC @ 0.5” ESP 3 3 4 4 5 5
Temperature Rise Range (°F) 35 - 65 35 - 65 35 - 65 40 - 70 35-65 40 - 70
Circulator Blower
Size (D x W) 10” x 8” 10” x 8” 10” x 10” 10” x 10” 11” x 10” 11” x 10”
Horsepower @ 1075 RPM
¹⁄₃ ¹⁄₃
½½¾¾
Speed 4 4 4 4 4 4
Vent Diameter³ 2” 2” 2” 2” 2” 2”
No. of Burners 2 3 3 4 4 5
Filter Size (in2)
Permanent
4
288 282 260 376 376 470
Disposable 576 564 564 752 752 940
Electrical Data
Min. Circuit Ampacity
5
9.4 9.4 13.8 13.8 12.2 13.2
Max. Overcurrent Device (amps)
6
15 15 15 15 15 15
Ship Weight (lbs)
132 135 135 156 173 175
1– Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.
2– DOE AFUE based upon Isolated Combustion System (ICS)
3– Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be either 2” or 3” in
diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on
installation/code requirements and must be 2” or 3” diameter PVC.
4– Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical
Codes. Extensive wire runs will require larger wire sizes.
5– Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the
same size as noted.
Notes:
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½” FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.