Product specifications

P
RODUCT
S
PECIFICATIONS
WFD195.02 www.whirlpoolcomfort.com 5
BLOWER PERFORMANCE
(CFM & Temperature Rise vs. External Static Pressure)
Model
Motor
Speed
Tons
AC at
0.5”
ESP
External Static Pressure, (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
WFD19
045S3BX
High 3 1,352 29 1,318 30 1,260 31 1,202 33 1,128 35 1,044 955 853
Med 2.5 1,214 32 1,172 34 1,123 35 1,064 37 1,012 39 938 859 741
Med-Lo 2 997 40 994 40 960 41 923 43 884 45 817 741 611
Low 1.5 757 52 753 52 734 54 704 56 674 59 620 524 438
WFD19
070S3BX
High 3 1,449 41 1,409 42 1,326 45 1,273 47 1,201 49 1,194 1,136 1,018
Med 2.5 1,192 50 1,172 51 1,141 52 1,094 54 1,046 57 973 904 793
Med-Lo 2 981 61 962 62 943 63 917 65 888 67 830 764 665
Low 1.5 750 79 730 81 714 83 692 86 657 90 620 570 502
WFD19
070S4CX
High 4 2,069 29 1,965 30 1,871 32 1,756 34 1,661 36 1,549 1,415 1,275
Med 3.5 1,752 34 1,724 34 1,667 36 1,603 37 1,488 40 1,402 1,290 1,082
Med-Lo 3 1,437 41 1,437 41 1,417 42 1,369 43 1,320 45 1,256 1,140 984
Low 2.5 1,184 50 1,177 50 1,161 51 1,132 52 1,095 54 1,047 928 837
WFD19
090S4CX
High 4 1,970 40 1,874 42 1,757 45 1,667 48 1,566 51 1,431 1,334 1,182
Med 3.5 1,713 46 1,650 48 1,572 50 1,510 52 1,418 56 1,313 1,211 1,079
Med-Lo 3 1,439 55 1,412 56 1,370 58 1,327 60 1,260 63 1,166 1,078 956
Low 2.5 1,183 67 1,155 69 1,122 71 1,108 72 1,062 75 1,011 931 816
WFD19
090S5CX
High 5 2,147 37 2,114 37 2,057 39 2,030 39 1,978 40 1,889 1,784 1,713
Med 4 1,675 47 1,686 47 1,640 48 1,623 49 1,557 51 1,501 1,455 1,360
Med-Lo 3.5 1,489 53 1,470 54 1,436 55 1,409 56 1,361 58 1,318 1,243 1,130
Low 3 1,307 61 1,265 63 1,234 64 1,203 66 1,168 68 1,096 1,053 991
WFD19
115S5DX
High 5 2,134 46 2,103 47 2,029 48 1,941 51 1,906 51 1,818 1,733 1,625
Med 4 1,678 58 1,643 60 1,643 60 1,577 62 1,527 64 1,489 1,423 1,339
Med-Lo 3.5 1,453 68 1,440 68 1,426 69 1,363 72 1,349 73 1,314 1,253 1,205
Low 3 1,259 78 1,239 79 1,220 80 1,181 83 1,159 85 1,118 1,082 1,015
Notes:
CFM in chart is without fi lter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return fi lters, this
chart assumes both fi lters are installed.
All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area
indicates ranges in excess of the recommended maximum heating static pressure.
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise
at a particular CFM, while ESP at the CFM will be lower.