Owner's Manual

Table Of Contents
7
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-Z240.1-latest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured according to the instructions in this document.
Four-wire power supply cord or cable must be used in a mobile
home installation. The appliance wiring will need to be revised.
See “Electrical Connection - U.S.A. Only” section.
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4
cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave
hood combination installation instructions for dimensional
clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls
with zero clearance.
A. 13" (33.0 cm) max. upper cabinet depth
B. 30" (76.2 cm) min. opening width
C. For minimum clearance to top of cooktop, see NOTE*
D. 30" (76.2 cm) min. opening width
E. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 7" (17.8
cm) max. from floor.
F. Cabinet door or hinges should not extend into the cutout.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than 1/4" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Electrical Requirements - U.S.A.
Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located on the frame behind a top
corner of the door or either side of the drawer.
A. The model/serial/rating plate is located on the frame behind a top
corner of the door or either side of the drawer.
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL listed, 40 or 50 A
power supply cord (pigtail). See the following Range Rating
chart. If local codes do not permit ground through the neutral,
use a 4-wire power supply cord rated at 250 V, 40 or 50 A and
investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 V 120/208 V Amps
8.8 - 16.5 kW 7.8 - 12.5 kW 40 or 50**
16.6 - 22.5 kW 12.6 - 18.5 kW 50
* The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.