Owners Manual
Table Of Contents
- RANGE SAFETY
- Range Safety
- RANGE MAINTENANCE AND CARE
- Self-Cleaning Cycle (on some models)
- General Cleaning
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements - U.S.A. Only
- Electrical Requirements ± Canada Only
- INSTALLATION
- Unpack Range
- Install Anti-Tip Bracket
- Adjust Leveling Legs
- Level Range
- Electrical Connection - U.S.A. Only
- Verify Anti-Tip Bracket Is Installed and Engaged
- Warming Drawer or Premium Storage Drawer (on some models)
- Storage Drawer (on some models)
- Oven Door
- Complete Installation
- Moving the Range
- SECURITE DE LA CUISINIERE
- Securite de la cuisiniere
- ENTRETIEN ET REPARATION DE LA CUISINIERE
- Cycle d'autonettoyage (sur certains modeles)
- Nettoyage general
- INSTRUCTIONS D'INSTALLATION
- SPECIFICATIONS
- Outils et pieces
- Exigences d'emplacement
- Specifications electriques ± E.-U. seulement
- Specifications electriques ± Canada seulement
- INSTALLATION
- Deballage de la cuisiniere
- Installation de la bride antibasculement
- Reglage des pieds de nivellement
- Ajustement de l'aplomb de la cuisiniere
- Raccordement electrique ± E.-U. seulement
- Verifier que la bride antibasculement est bien installee et engagee
- Tiroir-rechaud ou tiroir de remisage de qualite superieure (sur certains modeles)
- Tiroir de rangement (sur certains modeles)
- Porte du four
- Achever l'installation
- Deplacement de la cuisiniere
12
3. Depending on your model, remove plastic tag holding three
10-32 hex nuts from the middle post of the terminal block.
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4. Add strain relief.
Style 1: Power supply cord strain relief
■ Remove the knockout for the power supply cord.
■ Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
■ Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
■ Remove the knockout as needed for the flexible conduit
connection.
■ Assemble a UL listed conduit connector in the opening.
A. Removable retaining nut
B. Conduit
■ Tighten strain relief screw against the flexible conduit.
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL Listed, 250 V
minimum, 40 A,
range power
supply cord
4-wire connection:
Power supply cord
4-wire direct
A circuit breaker
box or fused
disconnect
4-wire connection:
Direct wire
3-wire receptacle
(NEMA type 10-50R
A UL Listed, 250 V
minimum, 40 A,
range power
supply cord
3-wire connection:
Power supply cord
3-wire direct
A circuit breaker
box or fused
disconnect
3-wire connection:
Direct wire