Dimension Guide

PRODUCT MODEL NUMBERS
Because Whirlpool Corporation includes a continues commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10553363B
05/05/2016
30" (76.2 cm) Freestanding Gas Range
WFG540H0A
WFG540H0E
WFG710H0A
WFG714HLA
WFG715H0E
WFG720H0A
WFG745H0F
Type of Gas
Natural Gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate is located on the
oven frame behind the top right side of the oven door has information
on the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified
on the model/serial rating plate for use with a different gas without
consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
Provide a gas supply line if
3
/
4
" (1.9 cm) rigid pipe to the range location.
A smaller pipe on longer runs may result in insuffient gas supply. With
LP gas, piping or tubing size can be
1
/
2
" (1.3 cm) minimum. Usually, LP
gas suppliers deteremine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA
design-certified, 4 to 5 ft (122
to 152.4 cm) long,
1
/
2
" (1.3 cm)
or
3
/
4
" (1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
A
1
/
2
" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the range.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
Electrical
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be provided.
CABINET OPENING DIMENSIONS
PRODUCT DIMENSIONS
M
H
A
B
C
D
E
L
G
I
K
J
F
A
B
C
A
B
C
D
E
F
A. 27
7
/
8
" (70.8 cm) max. depth
with handle
B. 36" (91.4 cm) cooktop height
(max.) with leveling legs
screwed all the way in*
C. 46
7
/
8
" (119.1 cm) overall
height (max.) with leveling legs
screwed all the way in*
D. 29
7
/
8
" (75.9 cm) width
E. 257/16" (64.3 cm) depth.
Back of range to front of
cooktop**
F. Model/serial rating plate
(located on the oven frame
behind the top right side of the
oven door)
IMPORTANT: Range must be level after installation. Follow the
instructions in the “Level Range” section. Using the cooktop as a
reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
** Front of door and drawer may extend further forward depending on
styling.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
®
TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
IMPORTANT: If installing a range hood or microwave hood combination
above the range, following the range hood or microwave hoods
combination instructions for dimensional clearances above the cooktop
surface.
A freestanding range may be installed next to combustible walls with
zero clearance.
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE *.
E. 30
1
/
8
" (76.5 cm) min. opening width
F. The shaded areas are recommended for installation of rigid gas pipe.
G. 11" (27.6 cm)
H. 17" (43.2 cm)
I. 2" (5.1 cm)
J. 4
1
/
2
" (11.4)
K. 3" (7.6 cm) min. clearance from both sides of range to side wall or
other combustible material.
L. Grounded outlet
M. Cabinet door or hinges should not extend into the cutout.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.