FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
Icon
Display
Text
Display
Explanation and Recommended Procedure
F36
Water Level Sensing Not Functioning
Pressure sensor failure detected (no signal, signal out of range,
or zero offset is too high).
Possible Causes
Check wiring harness to the pressure sensor and ACU.
Check the pressure hose.
Check for blocked pump filter (check all items listed in F03
error code section [Long Drain]).
Check the air trap and hose connection to pressure sensor.
Run the Service Test Cycle. If the error code persists,
F36 will be displayed.
F60
ACU Failure/Microprocessor Failure
An internal failure of the microprocessor has been detected.
Possible Causes
Check the ACU by running the Service Test Cycle.
If failure occurs, replace the ACU.
FAULT/ERROR CODES (cont.) — The fault codes below may be indicated
under various conditions and can be accessed through Service Diagnostics.