Instruction for Use

PAGE 23
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
COMPONENT REMOVAL
NOTE: Instructions are provided only for
those components where removal is not
obvious.
Components accessible through top panel:
Dispensing System
Door Switch/Lock Assembly
Interference Filter
Water Level Sensor
User Interface/Console – 1) Remove
cycle selector knob and then separate
UI from its housing.
Water Valve Assembly
Components accessible through back panel:
Drive Motor
Heater/Temp Sensor Assembly
Figure 10 - Pushing Lever on ACU
Lever (push in
direction of arrow)
Figure 11 - Releasing ACU Tabs from Cabinet
Tabs
(slide ACU to right to release)
Components accessible through bottom
of washer:
Drain Pump
Appliance Control Unit (ACU) – Gently lay
the washer on its right side (place a 2 x 4
or similar sized object on the floor prior to
laying the washer on its side to elevate the
washer slightly, making it easier to upright
it later). Remove the ACU screw on the
rear of the washer cabinet with a 7mm hex
nut driver. Push the plastic lever attached
to the ACU (see Figure 10), slide the
ACU to the right (toward the suspension
dampers), freeing the ACU tabs from the
ACU slots in the washer cabinet (see
Figure 11). Lift the ACU out of the washer
cabinet. When placing the washer upright,
make sure suspension springs remain
in place.
MANUALLY UNLOCKING
THE DOOR LOCK SYSTEM
1. Unplug washer or disconnect power.
2. Remove the base panel at the bottom
front of the washer.
3. Pull the ring-shaped tab protruding
at the lower right corner of the washer
(see Figure 9).
4. The door may be opened.
Figure 9 - Detail, Door Lock Assembly
Ring-Shaped Tab