Installation guide

Dryer Dimensions
LocationRequirements
Explosion Hazard
Keep flammable materials and vapors, such as
geaollne, away from dryer,
Place dryer at least 18 Inches (46 cm) above the floor
for a garage Installation,
Fallura to do so can result In death, explosion, or flra,
You will need
a A location that allows for proper exhaust installation. A gee
dryer must be exhausted to the outdoors. See "Venting
Requirements."
a A grounded eleotdcal outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
a A sturdy floor to support the dryer and a total weight (dryer
and load) of 200 Ibs (90.7 kg). The combined weight of a
companion appliance should also be considered.
= A level floor with a maximum slope of 1 in. (2.5 ore) under
entire dryer. (If slope is greater than 1 in. [2.5 cm], install
Extended Dryer Feet kit, Part No. 279810.) Clothes may not
tumble properly and models with automatic sensor cycles
may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45°F (7°(2)).At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored inan area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector
NOTE: No other fuel-burning appliance can be installed inthe
same closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
{_74 un)
(1
1
2
3
1. Small Opening Side-Swing Door
2. Large Opening Side-Swing Door
3. Wide Opening Side-Swing Door
4. Wide Opening Hamper Door
4
* Meet installations require a minimum in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area or closet
installation
The dimensions shown following are forthe minimum spacing
allowed.
a Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
a
a
a
For closet installation, with a door, minimum ventilation
openings inthe top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
a Companion appliance spacing should also be considered.
i
olo
24inA
m
IY
v
i
_6_ (2Scm)_5cm 14cm
1 2
m
D
_3"
_sm)
3
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents