Owners Manual
Table Of Contents
- Dryer Safety
- Dryer Safety
- Dryer Maintenance and Care
- Cleaning the Dryer Location
- Cleaning the Dryer Interior
- Removing Accumulated Lint
- Cleaning the Lint Screen
- Changing the Drum Light (on some models)
- Check Your Vent System for Good Airflow
- Maintain Good Airflow
- Nonuse, Storage, and Moving Care
- Special Instructions for Steam Models
- Installation Instructions
- Requirements
- Tools and Parts
- Location Requirements
- Gas Dryer Power Hookup – U.S.A. and Canada
- Gas Supply Requirements
- Installation
- Install Leveling Legs
- Make Gas Connection – U.S.A. and Canada
- Venting Requirements
- Plan Vent System
- Install Vent System
- Connect Inlet Hoses
- Connect Vent
- Level Dryer
- Complete Installation Checklist
- Sécurité de la sécheuse
- Sécurité de la sécheuse
- Entretien et réparation de la sécheuse
- Nettoyage de l’emplacement de la sécheuse
- Nettoyage de l’intérieur de la sécheuse
- Retrait de la charpie accumulée
- Nettoyage du filtre à charpie
- Changement de l’ampoule d’éclairage du tambour (sur certains modèles)
- Vérification d’une circulation d’air adéquate pour le système d’évacuation
- Pour maintenir une bonne circulation d’air
- Précautions à prendre avant des vacances, un entreposage ou un déménagement
- Instructions spécifiques pour les modèles vapeur
- Instructions d’installation
- Spécifications
- Outils et pièces
- Exigences d’emplacement
- Raccordement électrique de la sécheuse à gaz - états-unis et canada
- Spécifications de l’alimentation en gaz
- L’installation
- Exigences d’emplacement
- Raccordement au gaz - états-unis et canada
- Exigences concernant l’évacuation
- Planification des circuits de conduits
- Installation du conduit d’évacuation
- Raccordement des tuyaux d’alimentation
- Raccordement du conduit d’évacuation
- Réglage de l’aplomb de la sécheuse
- Liste de vérification pour installation terminée
17
2. Tighten and adjust leveling legs
If dryer is not level, prop up using a wood block. Use wrench
to adjust legs up or down, and check again for levelness.
Once dryer is level, make sure all four legs are snug against
the floor and the dryer does not rock.
3. Install and remove base trim (on some models)
To Install: Place the skirt to bottom of dryer and match the
locating pins with the holes. Press the skirt firmly upwards
until it snaps into place.
To Remove: On each corner, push down on top of base trim.
Rotate away from dryer and remove.
Complete Installation Checklist
q Check that all parts are now installed. If there is an extra part,
go back through steps to see what was skipped.
q Check that you have all of your tools.
q Dispose of/recycle all packaging materials.
q Check dryer’s final location. Be sure vent is not crushed or
kinked.
q Check that dryer is level. See “Level Dryer.”
q Remove film on console and any tape remaining on dryer.
q Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
q Refer to the user instructions in your Quick Start Guide.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Gas Models:
q Plug into a grounded 3 prong outlet.
q Check that gas supply is on.
q Check for leaks.
q Check that the flexible gas line is not crushed or kinked.
Steam Models Only:
q Be sure the water faucets are on.
q Check for leaks around “Y” connector, faucet, and hoses.
q If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the water
system in the dryer. Over time, the buildup of lime scale may
clog different parts of the water system, which will reduce
product performance. Excessive scale buildup may lead to the
need for certain part replacement or repair.
All Models:
q Set the heat cycle for 20 minutes and start dryer. Do not select
Air Only temperature setting.
If dryer will not start, check the following:
n Controls are set in a running or “ON” position.
n Start button has been pressed firmly.
n Dryer is plugged into an outlet and/or electrical supply is
connected.
n Household fuse is intact and tight, or circuit breaker has not
tripped.
n Dryer door is closed.
q When the dryer has been running for 5 minutes, open the dryer
door and feel for heat. If you feel heat, cancel cycle and close
the door.
If you do not feel heat, turn the dryer off and check to see
whether gas supply shutoff valve is open.
q If the gas supply shutoff valve is closed, open it and then
repeat the 5-minute test as outlined above.
q If the gas supply line shutoff valve is open, contact a qualified
technician.
n To change the door swing from a right-side opening to a left-
side opening, see online “Dryer Door Reversal Instructions” for
details.
If your Airflow screen reads “Check Vent,” your dryer vent may be
crushed or blocked.
NOTE: You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor will
go away.