Manual

Ventsystemchart
NOTE:Performanceofrearexhausttoeithersideofthedryeris
equivalenttoaddingoneelbow.Todeterminemaximumexhaust
length,addoneelbowtothechart.
Numberof Typeof Boxor Angled
90°turns vent Louvered hoods
orelbows hoods
0 Rigidmetal 64ft(20m) 58ft(17,7m)
Flexiblemetal 36ft(11m) 28ft(8,5m)
1 Rigidmetal 54ft(16.5m) 48ft(14.6m)
Flexiblemetal 31ft(9.4m) 23ft(7m)
2 Rigidmetal 44ft(13.4m) 38ft(11,6m)
Flexiblemetal 27ft(8,2m) 19ft(5,8m)
3 Rigidmetal 35ft(10.7m) 29ft(8.8m)
Flexiblemetal 25ft(7,6m) 17ft(5,2m)
4 Rigidmetal 27ft(8,2m) 21ft(6,4m)
Flexiblemetal 23ft(7m) 15ft(4,6m)
1. Installexhausthood.Usecaulkingcompoundtosealexterior
wallopeningaroundexhausthood.
2. Connectventtoexhausthood.Ventmustfitinsideexhaust
hood.Secureventtoexhausthoodwith4"(10.2cm)clamp.
3. Runventtodryerlocation.Usethestraightestpathpossible.
See"Determineventpath"in"PlanVentSystem."Avoid90°
turns.Useclampstosealalljoints.Donotuseducttape,
screwsorotherfasteningdevicesthatextendintotheinterior
oftheventtosecurevent.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.
Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Kit.
See "Tools and Parts" section for information on ordering.
1,
2.
Remove the red cap from the gas pipe.
Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe-joint compound on the threads of all non-
flared male fittings. If flexible metal tubing is used, be sure
there are no kinks.
A ............................_ _ ........................B
A. Flared male thread
B. Non-flared male thread
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use
TEFLON _t tape.
t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company•
10