Installation guide

3-wire
Power
Supply
Cord
Connection
Use
where
local
codes
permit
connecting
cabinet-ground
conductor
to
neutral
wire.
3-wire
receptacle
(NEMA
type
10-30R)
3-prong
plug
Spade
terminals
with
upturned
ends
Ring
terminals
f
1.
Remove
center
screw
ae
Ted
oman
|
A
|
Se
NSD
Remove
center
terminal
block
screw
(B).
(e
.
2.
Connect
neutral
wire
Connect
neutral
wire
(white
or
center)
(C)
of
power
supply
cord
to
center
terminal
block
screw
(B).
Tighten
screw.
(3.
Connect
remaining
wires
Connect
remaining
wires
to
outer
terminal block
screws.
Tighten
screws.
Finally,
reinsert
tab
of
terminal
block
cover
into slot
of
dryer
rear
panel.
Secure
cover
with
hold-down
screw.
Now,
go
to
“Venting
Requirements.”
DIRECT
WIRE
CONNECTION
Gh)
é
Fire
Hazard
Use
10
gauge
copper
wire.
Use
a
UL
listed
strain
relief.
Disconnect power
before
making
electrical
connections.
Connect
neutral
wire
(white
or
center
wire)
to
center
terminal
(silver).
Ground
wire
(green
or
bare
wire)
must
be
connected
to
green
ground
connector.
Connect
remaining
2
supply
wires
to
remaining
2
terminals
(gold).
Securely
tighten
all
electrical
connections.
Failure
to
do
so
can
result
in
death,
fire,
or
electrical
shock.
Direct
Wire
Strain
Relief
1.
Attach
direct
wire
strain
relief
Unscrew
the
removable
conduit
connector
screws
from
a
3/4"
(19
mm)
UL
listed
strain
relief
(UL
marking
on
strain
relief).
Put
the
threaded
section
of
the
strain
relief
(C)
through
the
hole
below
the
terminal block
opening
(B).
Reaching
inside
the
terminal block
opening,
screw
the
removable
conduit
connector
(A)
onto
the
strain
relief
threads.