Installation Instructions

15
5. Place the broil burner on the broil burner orifice hood. Insert
the broil burner locator pin in the hole in the oven back.
6. Position the broil burner against the roof of the oven cavity
and attach with screw.
To Convert Surface Burners (Natural Gas to LP)
1. If the burner grates are installed, remove them.
2. Remove the burner caps.
3. Using a Phillips or TORX
®
screwdriver, remove the burner base.
4. Apply masking tape to the end of a
9
/
32
" (7.0 mm) nut driver
to help hold the Natural gas orifice spud in the nut driver
while changing it. Press nut driver down onto the Natural
gas orifice spud and remove by turning it counterclockwise
and lifting out. Set the Natural gas orifice spud aside.
Use the following chart for correct LP gas orifice spud for each
burner. Refer to the model/serial/rating plate behind the control
panel for proper sizing of LP gas orifice spuds for each burner
location.
A
B
A. Broil burner orifice hood
B. Broil burner
A
B
C
D
A. Burner cap
B. Gas tube opening
C. Burner base screws
D. Burner base
A
A. Natural gas orifice spud
LP Gas Orifice Spud Chart
Burner Rating Color Number
4,000 BTU Blue 64L
7,000 BTU Black 81L
9,100 BTU Green 97L
14,000 BTU Red 114L
5. Replace the Natural gas orifice spud with the correct LP gas
orifice spud. See the “LP Gas Orifice Spud Chart.”
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with package containing literature.
10. Replace burner grates.
11. Complete installation. See the “Make Gas Connection”
and “Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the Low setting for
each cooktop burner. See “Adjust Flame Height” in the
“Electronic Ignition System” section.
Natural Gas Conversion
1. Turn manual shut-off valve to the Closed position.
2. Unplug range or disconnect power.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A. To range
B. Shut-off valve (Closed position)
C. Gas supply line