Specifications

12
System runs continuously—little
cooling/heating.
Shortage of refrigerant. Test for leaks. Add refrigerant.
Restricted liquid line. Replace restricted part.
Open element or limit on electric heater (heating only). Test heater element and
controls.
Dirty air filter. Inspect filter; clean or replace as needed.
Dirty indoor coil. Inspect coil and clean, if needed.
Not enough air across indoor coil. Check blower speed. Check duct static pressure and
filter.
Infiltration of outdoor air. Check windows, doors, vent fans, etc.
System undersized. Refigure cooling load.
Broken valves. Test compressor efficiency.
Inefficient compressor. Test compressor efficiency.
Wrong type of expansion valve. Replace valve.
Expansion valve restricted. Remove restriction or replace valve.
Oversized expansion valve. Replace valve.
Undersized expansion valve. Replace valve.
Inoperative expansion valve. Check valve operation. Replace if needed.
Flowrator not seating properly. Check flowrator and seat, or replace flowrator.
Too cool/warm and then too warm/
cool.
Faulty thermostat. Test continuity of thermostat and wiring. Replace, if needed.
Improper cooling anticipator. Check resistance of anticipator.
Improperly located thermostat. Relocate thermostat.
Airflow unbalanced. Readjust air volume dampers.
Not cool enough on warm days. Dirty air filter. Inspect filter; clean or replace as needed.
Dirty indoor coil. Inspect coil and clean, if needed.
Not enough air across indoor coil. Check blower speed. Check duct static pressure and
filter.
Noncondensibles. Recover charge. Evacuate and recharge.
Recirculation of condensing air. Remove obstruction to airflow.
Infiltration of outdoor air. Check windows, doors, vent fans, etc.
System undersized. Refigure cooling load.
Wrong type of expansion valve. Replace valve.
Expansion valve restricted. Remove restriction or replace valve.
Undersized expansion valve. Replace valve.
Certain areas too cool, others too
warm.
Dirty air filter. Inspect filter; clean or replace as needed.
Dirty indoor coil. Inspect coil and clean, if needed.
Not enough air across indoor coil. Check blower speed. Check duct static pressure and
filter.
Infiltration of outdoor air. Check windows, doors, vent fans, etc.
Airflow unbalanced. Readjust air volume dampers.
Problem
No Cooling/Heating Cause/Test Method and/or Solution