Installation Instruction

20
1. Prepare to connect neutral bond
wire and neutral wire
B
E
A
Remove center terminal block screw (B). Remove neutral bond
wire (E) from external ground conductor screw (A).
C
E
B
2. Connect neutral bond wire and
neutral wire
Connect neutral bond wire (E) and neutral wire (white or center
wire) (C) of power supply cord or cable under center terminal
block screw (B). Tighten screw.
3. Connect remaining wires
Place remaining wires under outer terminal block screws
(hooks facing right). Tighten screws.
A
G
4. Connect external ground wire
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
“Venting Requirements.
IMPORTANT: You must verify with a qualied electrician that
this grounding method is acceptable before connecting.
4. Connect remaining wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
“Venting Requirements.
B
C
Place hooked end of neutral wire (white or
center) (C) of direct wire cable under center
terminal block screw (B). Squeeze hooked
end together. Tighten screw.
3. Connect neutral wire
Optional 3-Wire Connection