Owners Guide

5
Universal Wall—Sleeve Dimensions
1. Identify the wall-sleeve brand installed in the wall, and make
sure that dimensions of wall-sleeve are as per the below table:
Type
Wall-sleeve Dimensions
Height Width Depth
Standard Dimension 15¾" 26" 16¾"
NOTE:
All wall sleeves, used to mount the new air conditioner must
be in sound structural condition and have a rear grille that
securely attached to the sleeve, or rear ange that serves as a
stop for the air conditioner.
If non-Whirlpool brand wall-sleeve installed, make sure that
the dimension is suitable for the product.
The selected wall-sleeve must be installed and fastened to
the wall with the screws.
IMPORTANT: When installation is complete, replacement unit
must have rearward slope as shown in below gure:
2. Remove the old air conditioner from wall sleeve and prepare as
follows:
Clean interior (Do not disturb seals).
Check the wall sleeve to make sure that it is securely
attached to the wall before installing.
Repair painted surface if needed.
3. If the ground wire hole does not exist, drill a 3/16" pilot hole for
the ground screw through the left hand side of the sleeve, in
a clear area about 3 inches max. back from the front edge as
shown in below gure:
4. Pull the loose end of the ground wire out of the front of
the sleeve and bend it away from the opening. This will be
attached to the air conditioner once installed.
Rear
Wall Sleeve
Level
1/4" to 5/16"
Front
Sleeve
W
all sleeve to unit
Gr
ounding.
3/16"Pilot Hole
3"
Max
1"
DIMENSIONS PART QUANTITY
1" x 3/4" x 14" Seal Sponge 2
1" x 3/8" x 14" Seal Sponge 2
1" x 3/8" x 25" Seal Sponge 3
1" x 1½"x 25" Seal Sponge 3
1" x 1½" x 14" Seal Sponge 2
1" x 1½" x 84" Seal Sponge 1
3¾" x 1½" x 4" Seal Cotton 4
3/4" x 1½" x 17" Seal Cotton 2