LOCATION REQUIREMENTS
Consider the following when selecting an installation
location for the Central Water Filtration System.
= Do not operate the Central Water Filtration System
where freezing temperatures occur. Do not attempt
to treat water over 120ºF. Freezing temperatures or
hot water damage voids the warranty.
= To condition all water in the home, install the
Central Water Filtration System close to the water
supply inlet, and before all other plumbing connec-
tions, except outside water pipes.
= Install the Central Water Filtration System between
the home’s incoming water supply and the water
softener, if one is being used (See Figure 3).
= A nearby drain is needed to carry away Clean
Rinse discharge water. Use a floor drain, laundry
tub, sump, standpipe, or other options (check your
local codes). See "Air Gap Requirements" and
"Valve Drain Requirements" sections. If a drain is
not available, it is still possible to operate the
Central Water Filtration System in a manual Clean
Rinse mode. See “Operating in Manual Clean
Rinse Mode.” The automatic Clean Rinse must be
disabled if the Central Water Filtration System will
not be connected to a drain (See Page 7).
Installation Requirements
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
FIG. 3
Pressure
Tank
City Water Supply
Well Water Supply
Well
Pump
OR
Central
Water
Filtration
System
Optional
Sediment
Filter
Water
Heater
Water
Softener
Untreated Water to
Outside Faucets
Hot Water
to House
Cold Water
to House
= The Central Water Filtration System works on
24 volt, 60 Hz electrical power only, supplied by a
direct plug-in transformer (included). Provide an
electrical outlet in accordance with NEC and local
codes.
= Do not install the Central Water Filtration System on
a hot water line (See Figure 3, below).
= Avoid installing in direct sunlight. Excessive sun
heat may cause distortion or other damage to non-