SPECIFICATIONS
Model WHELJ1
Rated Service Flow Rate 6.0 gpm (22.7 L/min.)
Pressure Drop at Rated Service Flow
10 psig
* (68.9 kPa)
Pressure Drop at 9.6 gpm
15 psig
* (103.4 kPa)
Water Pressure Limits (minimum / maximum)
30 - 125 psi
(206.8 - 861.8 kPa)
Water Temperature Limits (minimum / maximum) 40 - 100 °F (5 - 38 °C)
Drain Flow Rate 3.4 gpm
0.50 ppm
0.75 ppm
Rated Capacity at Chlorine Concentration** of: 1.0 ppm
1.5 ppm
2.0 ppm
2,280,000 gal.*
1,520,000 gal.*
1,140,000 gal.*
760,000 gal.*
570,000 gal.*
Sediment Removal with 30-40 micron particle size 95% or more
Sediment Removal with 40-50 micron particle size 99% or more
* From independent laboratory test data.
** Typical residential chlorine concentration is 0.5 to 1.0 ppm.
This system conforms to NSF/ANSI Standard 42 for the specific performance claims
as verified and substantiated by test data.
Specifications & Performance Claims
This system has been tested according to NSF/ANSI 42 for the reduction of chlorine taste and odor. The concentra-
tion of the indicated substance in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI 42.
While testing was performed under standard laboratory conditions, actual performance of the system may vary
b
ased on local water conditions.
PERFORMANCE CLAIMS
Substance
Influent
Challenge Level
Reduction
Requirement
Average Percent
Removal
Chlorine 2.0 ±10% mg/L 50% 82.8%
Questions? Call Toll Free 1-866-986-3223 or visit whirlpoolwatersolutions.com
When you call, please be prepared to provide the model and serial number,
located on the rating decal on back of the cover.